Price is to reconnect to existing pop up assembly (if possible) and run new Ptrap. Cut out section of ABS drain in wall and run new pvc line. 6/24/25 Returned and cut out section of leaking ABS pipe and ran occ back to the stub out for the waste arm. Connected a new trap to the existing pop up and removed the nail sticking out that hit the previous pipe. Had recommended replacing the pop up with initial phone pricing given to customer due to the age and condition of the pop up. Also, the threads had broken at some point. Customer wanted to avoid replacing the pop up if possible. Connected to the existing pop up with a grey rubber coupling. Made customer aware that since this isn’t the recommended repair for the pop up, that if there are any issues, then additional pricing will have to be given to replace the pop up. Asked customer to give the sink 2 hours for the glue to fully cure before use after testing with cold water.