4720 Industrial Access Rd.
Douglasville, GA 30134
770-445-8923

Job Locations
for newnan, ga


Map of Newnan GA
Dobbs Technician A.

Dobbs Technician A.


Job Checkin

DCM1: Heat complete, replaced 20x20x1 filter. System is fully functional and operating within manufacturer specifications at this time. Refrigerant pressures and temperatures are appropriate for indoor and outdoor weather conditions. Found there is no surge protector on outdoor system, due to Rheem having a known issue of drive boards failing when voltage drops recommend investing in a surge protector that monitors voltage spikes and drops. Unable to add union to drain line due to how close p-trap is to coil exit port, recommend upgrading drain to be able to clean sludge out of drain line and ensure proper drainage. System does not have an SS2 water safety, there is a drain pan switch but adding an SS2 would shut system off before water overflowed primary drain pan if drain line did clog.

BESbswy