Client called us out today due to a few different water pressure issues going on throughout the home. They recently purchased the home in the last couple months. The master bathroom toilet was loose and the master shower had a constant drip. We replaced the failed single handle shower cartridge with new of same model due to the drip In master shower. Put trim back on and tested, all good there. We were going to have to pull the master toilet regardless to inspect the toilet flange, so client decided to have us install a new American standard toilet in place of the old glacier bay toilet. Shimmed it to make it sturdy, then caulked around the base after testing. All good there, recommend client give it til the morning for the caulk to set up on the toilet. We replaced the low grade plastic house pressure reducing valve with a new dual chamber watts 25aub pressure reducing valve, and replaced the old gate valve with a new ball valve so customer can confidently use in future if needed.