Customer having pressure issues and hose Bibb leaking upon arrival. Customer stated when he runs the kitchen sink and uses another fixture the pressure drops significantly. After running 2 fixtures and having my pressure gauge hooked up the pressure went from 75 to 30 psi. Informed customer we could replace the PRV and whole house shutoff. Informed customer we could replace the hose Bibb outside as well. Gave customer estimate, customer approved estimate. Installed new PRV and new whole home shutoff valve, also installed new hose Bibb. Turned water back on to check for leaks and set the pressure. Found no leaks. After turning water back on to hose Bibb with a gate valve customer had shutoff, the gate valve had a slow drip. Informed customer that I could tighten the packing nut to see if that would fix the issue, tightened up packing nut and valve no longer has slow drip. Informed customer to keep an eye on it. Set pressure to 60 psi. No leaks upon departure and hose Bibb is working pro