Hardness 4 PH 7.6 Pressure 50psi Chlorine .3ppm Annual plumbing inspection completed. Majority of the home has been repiped in pex and all new drains and shut off valves. I tested all shut off valves and all turn very easily and no leaks at this time. We had recently rebuilt the toilets in the home, customer stated that the one toilet still runs on occasion. I discovered that the chain linkage was very tight, I then gave the chain some slack and now the toilet is holding water. I dye tabbed the toilet, after the adjustment, and it has past my test. Throughout the inspection, I did discover that the lav sink was slowly draining and there is no bonding wire on the water heater. I supplied and installed a bonding wire for the water heater and unclogged the lav sink for the client as a curtesy at this time. I advised to the client, that the lav faucets and kitchen faucets are of lower quality and were purchased on the internet, client would like a quote for three faucets installed, clien