Carlos knows his job and equipment well. His experience shows.
We were so fortunate to find Vern‘s plumbing available very quickly and with the best of service from the phone calls and text messages and alerts to the fine young man, Christian, who came to our door and so cordially and efficiently corrected our problem in record time.
Very friendly,on time and quick service!!! Accomplished the job!!
The technician immediately identified the problem with the toilet, but the price was too high for my budget.
Christian was so personable, knowledgeable & resolved our plumbing issues. I am so glad we called “Vern’s Plumbing” & would recommend this company to everyone.
Christian and Matt arrived the same day to take care of an urgent issue They were patient in explaining the steps of the process and we’re both polite and professional Christian was very helpful and friendly. I would recommend him and this company to anyone.
I called Vern’s Plumbing to schedule a technician to come to my residence to inspect a broken main sewer pipe. Christian (the technician) arrived on time to my residence in Spotsylvania County. Christian took the time to talk with me about my problem and to inspect the broken pipe and the surrounding area. Most importantly, he explained to me what was happening with the pipes underground, at my residence, and what services Vern’s Plumbing could offer me. I was impressed with his confidence and his willingness to solve my problem. He did not provide me with an estimate because other gas, water, electric, and cable lines were buried very near by to my broken sewer pipe. As soon as the line locations are marked by the county, Christian said he would return to my residence to give me an estimate for the project. I should also mention that my broken pipe is 9 feet underground and presents a challenging dig.
Fast, tidy, knowledgeable, and caring. Fantastic service provided by Carlos Perez-Mojica from Vern's Plumping.
Chris L came out to assess some issues we had and he started breaking down everything that was going on. Calm and well mannered, very good experience.
Chris was great. Best attention to detail and customer service I have received in this area for plumbing. Thank You!
Hose bib located in the front of the home has ruptured in the wall. Bib needs to be replace asap. Also recommend we install a new main water shutoff valve and pressure reducing valve while we’re at it. Existing main valve is a full turn ball valve and the pressure reducing valve is starting to corrode. Both of these items are original with the home. Could not relocate the main valve anywhere in the home because of the way the water lines are plumbed. Emailed copy of invoice and estimates to homeowners email.
Tested (6) backflow preventers. Location: water heater mechanical room back of building Use: fire Type: dc Make: Ames Model: colt 200 Serial Number: UC-2042 Size: 4 INCH 1st check: 3.0 2nd check: 3.0 Relief: N/A Water Pressure: 62PSI Location: WATER HEATER MECHANICAL ROOM BACK OF BUILDING Use: DOMESTIC WATER Type: DC Make: APOLLO Model: DCLF4A Serial Number: 75005 Size: 3 INCH 1st check: 3.0 2nd check: 3.0 Relief: N/A Water Pressure: 62 PSI Location: GROUNDS CREW SHOP Use: IRRIGATION Type: PVB Make: APOLLO Model: PVB4A Serial Number: 80000A Size: 1-1/2 INCH 1st check: 1.0 2nd check: 2.4 Relief: N/A Water Pressure: 62 PSI Location: FIRE SPRINKLER ROOM 3RD BASE SIDE Use: FIRE Type: DC Make: APOLLO Model: DCLF4A Serial Number: 74548 Size: 4 INCH 1st check: 3.0 2nd check: 3.0 Relief: N/A Water Pressure: 68 PSI Location: BOX OFFICE SPRINKLER ROOM Use: FIRE Type: DC Make: AMES Model: COLT 200 Serial Number: UB-2410 Size: 4 INCH 1st check: 2.6 2nd check: 3.6 Relief: N/A Water Pressure
Arrived at location and inspected 3 comp sink in kitchen. Connections to basket strainers are leaking. They would like a quote on replacing all piping. Also inspected tankless water heater for an error code exhaust blockage. The previous company did not get fresh air for these units from outside, these 5 units get fresh air from inside the laundry room. This is causing the inlet fresh air screens to get clogged with dryer lint. Removed dryer lint and reset tankless. It is working as should. Also mentioned to me one day they had no hot water on the 4th floor but the following day they had no issues.
Performed whole home PMA inspection and changed out 20” whole house filter. All plumbing in the home is working as it should at this time with no issues. Gave the homeowner the option to renew her gold membership while I was onsite. She has to wait for her monthly check to come in so she can pay for it, she will contact the office when that time comes. Emailed copy of invoice and estimates to homeowners email.
Arrived at the location and check the toilet filler valve and adjust it and it is working properly job complete
Customer needs prv and expansion tank replaced. Water heater is sitting in water and customer says its done that since install he change the temperature and pressure valve and its still doing this. Customer has a gas line that needs reduced for the stove to be able to move back farther to the wall. Left estimates at this time
Installed new 2” toilet flapper in hallway bathroom, 3/3” pressure reducing valve and 2.5 gallon expansion tank on existing 50 gallon NG water heater. All items are worming as they should at this time with no issues.
Auger the master bathroom and hallway toilet. Customer had clogged both toilets in the home. I augered and tested to be sure they flushed and the toilets are working as they should now
Run an auger through the toilet to clear blockage. Tested and checked to make sure the toilet was flushing and the toilet is working as intended
Camera the sewer line and found that the pipe is broken and alot of root is inside the sewer line and going to send a quote for replacing the sewer line outside the house and 3 inch pvc pipe Email is Paulandvictoria1@gmail.com
Cut out tee and replace female adapters on expansion tank and replace expansion tank. Customer initially called for a leak but they will cut. The ceiling theirselves but while I was here I noticed the expansion was leaking and the female adapters had some bad corrosion on it so we cut that out and replaced it
Put a Rebuild kit for the spigot out the building and trun back the water and test and show to the manager on site job is complete
Trun off the main valve for the building and replace the cartridge for the shower in room 509 turn back the water and flush the system out and it was coming yellow water in and flush the system into clear water came out in the faucet and tub there is going to be a little of the yellow in all the room I to everything come out of the system just incase customer complained
Attempted to test 3 backflow preventers. Domestic water: 2 inch RP Make: watts Model: 909HWM1QT - inlet ball valve froze and split Fire sprinkler bypass? 1-1/2 inch RP Make: watts Model: 909M1QT - this backflow has an alarm on the inlet gate valve. Fire sprinkler 4 inch DC Make: Ames Model: 2000SS inlet and outlet valves are not holding for technician to replace #3 test port valve. That test port valve froze and split. Recommended to replace all 3 backflow due to freezing.
Installed new 3/4” pressure reducing valve and main water shutoff valve in crawl space, both items are working as they should at this time with no issues. Pressure in the home is set at 70 psi. Emailed copy of todays invoice to homeowners email.