Christopher W. Job Checkin

Install new 85 gallon pressure tank with tank tee kit and serviced existing 1054 water right IMPBF acid neutralizer. Both units are working as they should at this time with no issues. New pressure tank comes with a 5 year warranty from the manufacturer. Homeowner needs to start putting salt in the salt tank for the water softener. Tank is currently empty and holding water. Homeowner signed up for the yearly salt maintenance contract. This will include the replacing the 10” whole house filter. Went ahead and topped off the salt tank while I was onsite today. Please contact the homeowner to schedule the salt visits, we need to come out every 4 months to service the unit. UV bulb will have to be replace in 57 days, went ahead and emailed homeowner the estimate for us to replace the bulb. Left 4 bags of salt and one 10” 5 micron whole house filter. Emailed copy of invoice and estimates to homeowners email.


Christopher  W.

Christopher W. Job Checkin

Existing 85 gallon pressure tank was only holding 24 psi on the bladder side. Tried putting the correct amount of air in the tank, but had no success. This tells me the bladder inside the tank has ruptured. Tank needs to be replaced asap. Changed 10” whole house filter because the existing filter was complete toast. Even with the new filter installed the water pressure inside the home was very poor. Ended up isolating each water right filtration unit to see if they were the cause of the pressure issue. Turns out the 1054 IMPBF acid neutralizer is the cause of this issue, once that unit was isolated water pressure to the home was restored. Filter needs to be removed and serviced asap. Filter had been bypassed for the time being. Water pressure at the kitchen sink is still lazy because the sprayer head is compromised. I know this because the pressure is absolutely phenomenal without the sprayer head. Sprayer head needs to be replaced or the faucet needs to be replaced.


Carlos P.

Carlos P. Job Checkin

Took out the toilet and put a new wax ring and bolt and seal around the toilet flush couple of times and no leak Found job job is complete


Carlos P.

Carlos P. Job Checkin

Camera and locate sanitary sewer.

Camera and locate sanitary sewer.

Christian L.

Christian L. Job Checkin

Leaking sink.

Leaking sink.

Christian L.

Christian L. Job Checkin

Repipe kitchen sink and vanity.

Repipe kitchen sink and vanity.

Nathan K.

Nathan K. Job Checkin

Free estimate to run new waterlines for wash bay area.

Free estimate to run new waterlines for wash bay area.

Christian L.

Christian L. Job Checkin

Bathroom drain is leaking.

Bathroom drain is leaking.

Nathan K.

Nathan K. Job Checkin

Attempted to locate remaining hosebibs around the home Removed drywall in three areas in attempt to locate waterlines supplying hosebibs Unfortunately within the holes cut the technician did not find the water piping, remeasured from exterior wall and attempted to locate bibs Basement layout may have hidden gaps or false walls not allowing the technician to access the interior wall to replace the hosebibs We would like to come back with a second technician to help locate lines Having a second set of eyes to create sounds or movement in piping can better help locate waterlines within the wall


Nathan K.

Nathan K. Job Checkin

Installation of a new frost free hosebib on the side of the home near the generator Customer mentioned another tech had recently replaced this however we do not install Wolverine brass hosebibs, and I could not find any past invoices regarding this bib Installed a new 1/2 shut off valve just before the bib, traced out line however could not find an existing shut off for this hosebib


Christopher  W.

Christopher W. Job Checkin

Wrote estimate to install IMPRC water softener in basement utility room. Unit comes with a lifetime warranty on the tank and 1 year warranty on all parts. Emailed copy of today’s invoice and estimates to homeowners email. Hardness- 9 grains Chlorine- 2.2 ppm TDS- 250


Nathan K.

Nathan K. Job Checkin

Cleared second floor toilet with closet auger Technician recommended possibly replacing the upstairs hall bathroom toilet, it’s possible the interior enamel surface is no longer smooth and is catching most of the debris passing through the toilet. Last visit the master bathroom toilet was pulled and ran the camera through, this ruled out any possible drain line issues or venting issues This leads us to believe a new toilet could solve any further issues with flushing


Nathan K.

Nathan K. Job Checkin

Pull master bathroom toilet and camera the drain from the toilet flange


Nathan K.

Nathan K. Job Checkin

Gave customer an estimate to pull the upstairs master bathroom toilet and camera from the flange Customer believes one of the blue toilet pucks fell from the tank into the flush valve One of these pucks siting within the drain line can cause issues with the toilets, especially if blocking the vent Pulling the upstairs bathroom toilet and camera will allow us to further inspect the drain for issues or any blockages in the line


Matthew W.

Matthew W. Job Checkin

Tested 3 backflow preventers. The 4th backflow that is listed on Panera account was in a vacant space next door to them. And that space is now a wing stop. Backflow with serial number 263491 which was in the vacant space is no longer in use and was removed by others when wingstop was built. Location: Dishwasher Use: domestic water Type: rp Make: watts Model: LF009M2QT Serial number: 192113 Size: 2 INCH 1st check: 9.0 2nd check: 7.0 Relief: 3.0 Water PSI: 110psi Pass Location: fire sprinkler room Use: irrigation Type: rp Make: watts Model: LF009M2QT Serial number: 237550 Size: 1 INCH 1st check: 8.5 2nd check: 7.5 Relief: 2.5 Water PSI: 110PSI Pass Location: FIRE SPRINKLER ROOM Use: FIRE Type: DC Make: AMES Model: COLT200 Serial number: WF2146 Size: 4 INCH 1st check: 2.0 2nd check: 2.0 Water PSI: 110PSI Pass