Great company, responsive and such knowledgeable, polite techs. Our go-to! Christopher finished our last job in an hour. We are well taken care of by Vern’s!
Liam was amazing in his knowledge and advice and provided excellent service for 2 urgent leaks we had. Highly recommended! Our go-to plumbing company!
Professional and on time, Chris performed the task well and even helped provide answers to my extra questions. Would recommend.
Prompt, courteous, knowledgeable and efficient in his work!
Chris was on time, worked efficiently and resolved the issue
Arrived at the guest house of the right side and took pictures and information and going to send a quote for replacing the water heater
Pull toilet in bathroom and snake main line from toilet drain Ran all of my cables, 6 , and still didn't break through checked the septic tank and it's full need a septic company
Customer doesn't want inspection today. Customer had a yard hydrant that handle wasn't lined up properly but I was able to readjust the handle and now it isn't leaking. Customer is informed on needed a rebuild kit if this happens again
1/2” copper line looping the heat exchanger inside the heater has ruptured. Unfortunately there’s no type of repair I can perform to fix this issue because the line is attached to the heat exchanger. Homeowner needs to contact the manufacturer to get a replacement heat exchanger or replacement heater. He will contact the office once he has all of his ducks in a row. Emailed copy of invoice to homeowners email.
Replaced moen cartridge assembly under warranty, found the existing cartridge was broken and not sealing correctly internally After replacing the cartridge restored water and tested for any further issue or leaks Cartridge is working as should with no leaks at the time
Completed work. Pipe leak repair on outlet side of middle backflow preventer.
PO#71213 Complete repair of (2) 2 inch Watts 909M1 RP Backflow preventers. - Breakdown and removal of existing checks and reliefs. - Cleaning of inside valve bodies of both units. - Installation of new repair parts. - Re testing of both units once work is done. - While water is off, repairing of a 2 inch sweat 45 fitting to repair leak. --- Water will need to be turned off to these devices while work is being done. 08/13/2024 Complete repair on (2) RP style backflows. Was unable to turn water off to the building. Will need to reschedule water line repair for the following days. Wednesday or Fridays after 5pm or Saturday early morning. Lower backflow test results after repair. Use: Domestic water Location: Sprinkler Room Size: 2 inch Make: Watts Model: 909M1QT Type: RP Serial Number: 442375 Water Pressure: 80 psi. 1st check: 8.0 2nd check: 7.0 Relief: 4.0 Passed Middle backflow test results after repair. Use: Domestic Water Location: Sprinkler room Size: 2 inch Make: Watts Model:
Install zoeller M267 sewage ejector pump with new lid and combination check valve. Pump comes with a 3 year warranty from the manufacturer. New pump is working as it should at this time with no issues. For some reason the new lid hardware would not screw into the existing croc, ended up caulking until I couldn’t caulk anymore. Told the homeowners to contact is if they have any issues. Sent copy of todays invoice to homeowners email.
Existing/original sewage ejector pump has failed. Will return to install new pump, lid and combination check valve on 08/07/24. Homeowner will contact the office after he confirms the time frame with his wife. Sent copy of todays invoice/estimate to homeowners email.
Snake the kitchen drain and put 5 cable with the k 50 machine also run water to see any back up and line is open and clean job is complete Note please send invoice to mailbox
Customer was lpoking for estimstes on a softener and a pressure tank. Also left one for a whole house filter due to sediment in the lines making it to the fixtures.
Sent water softener estimates to homeowners email and discussed VP membership so they can get the best deal possible. Highly recommend installing a 1354 IMP water right softener to correct the hardness/calcium in the water, this unit will prevent calcium deposits from building up on/inside the fixtures and ruining them over time. Home is only 5 weeks old Hardness- 8 PH- 7.4 Iron- 0 TDS- 134
Repaired pipe leak in ceiling of basement and repaired water line leak off of main waterline. Tested both repairs with no issues issues at this time. Replaced failing 50 gallon electric water heater and tested upon completion. No leaks or issues at this time. Referred homeowner to water damage restoration company. Clients now Gold Vo members Paid in full yesterday
Sold gold membership and will be returning tomorrow to complete two pipe repairs and replace leaking water heater.