Matthew W.

Matthew W. Job Checkin

PO 4500082924 Installation of 2 new test ports on domestic water backflow. Water will need to be turned off while work is being done. PO 4500082924 Rebuilding of a 4 inch Ames 2000SS Backflow Preventer. This includes replacement of the 1st and 2nd checks as well as cleaning of the inside of the backflow. Re-testing of unit once work is completed. For fire sprinkler backflows, the fire alarm must be called out / placed in test or on hold prior to work starting. Repaired 4 inch fire sprinkler backflow and tested. Installed 2 new test ports on domestic water backflow. Location: fire sprinkler room Use: fire Type: DC Make: Ames Model: 2000SS Size: 4 inch Serial number: 19506 1st check: 4.0 2nd check: 3.5 Water pressure: 55 PASS


Matthew W.

Matthew W. Job Checkin

Tested (3) backflow preventers. 2 out of the 3 passed testing. Location: fire sprinkler room inside building Type: rp Use: Domestic water Make: watts Model: 009M2QT Serial number: 168567 Size: 2 inch 1st check: 9.0 2nd check: 7.5 Relief: 3.0 Passed This backflow needs (2) new test ports. Both test ports leak when turned on and off. Had to temporarily Cap them to stop leak. Location: fire sprinkler room inside Type: dc Use: fire Make: Ames Model: 2000SS Serial Number: 19506 Size: 4 inch 1st check: 0.0 2nd check; 3.5 Failed First check has failed Location: fire sprinkler room inside Type: rp Use: irrigation Make: Wilkins Model: 975xl2 Serial number: ACL5810 Size: 2 inch 1st check: 8.9 2nd check: 8.0 Relief: 3.0 Passed


Matthew W.

Matthew W. Job Checkin

Tested (1) RP backflow preventer. Location: fire sprinkler room outside access Use: Domestic water Type: RP Make: watts Model: LF009M2QT Size: 2 inch 1st check: 9.8 2nd check: 8.5 Relief: 3 Water pressure: 60psi Pass


Nathan K.

Nathan K. Job Checkin

Service Summary: We initially replaced the flapper and fill valve, as the toilet was not flushing properly and the fill valve was not functioning correctly. After installation, the toilet flushed properly for 3-4 test runs, but it became clogged during testing. We used a closet auger to attempt clearing the debris from the toilet trap, which had a significant buildup of debris. When this didn’t work, we ran the lavatory sink to check for mainline stoppages. Bubbles formed in the toilet, indicating a blockage in the main line. We removed the toilet and used our K60 machine, running all 6 cables on the truck. After waiting for additional cables, we ran 2 more cables and successfully cleared a paper towel blockage in the line. We then ran the lavatory sink and tested the drain line with a 5-gallon bucket to ensure there were no further stoppages. Upon attempting to reset the toilet, we noticed the flange was misaligned, causing leaks when tested. The toilet was removed again, and we r


Matthew W.

Matthew W. Job Checkin

Tested one backflow preventer Location: fire sprinkler room Use: Domestic water Type: DC Make: Wilkins Model: 950XLT2 Size: 2 inch Serial number: AEB0831 1st check: 1.5 2nd check: 2.0 Water pressure: 60psi Pass


Carlos P.

Carlos P. Job Checkin

Turn off the main water valve and replace the moen cartridge and turn back the water and flush the system out into water came out in the faucet test the shower and the owner also check it out and everything is working properly job is complete


Carlos P.

Carlos P. Job Checkin

In the women's bathroom I replace the sensor in the handicap toilet and in the left side toilet and one sensor flush on the right side in the men's bathroom flush it couple of times and all 3 flush sensor are working properly job is complete


Carlos P.

Carlos P. Job Checkin

Took out the garbage disposal and check both leg and put the one was moving and tighten both again


Carlos P.

Carlos P. Job Checkin

We shall furnish and install new, 2hp 3-phase commercial kitchen garbage disposal. And also replace the sprayer faucet next to the dishwasher test it and no leaks found job is complete


Carlos P.

Carlos P. Job Checkin

Arrived at the location and check the garbage disposal and it was disconnected from the braket I put it back on and run water to see any leak and no leaks found also the going to send a quote for replacing the solenoid and the garbage disposal flange and the garbage disposal and the box that turn on and the garbage disposal did a temporary fix into It get fix


Christian L.

Christian L. Job Checkin

Customer had a remodel done in the kitchen and had a deeper sink installed. The pipes coming from.the garbage disposal are having to run uphill to get to the drain. They need the sink repiped and garbage disposal removed and the drain lowered to now catch the sink with proper flow.


Christian L.

Christian L. Job Checkin

Left estimates to fix gas line and replace water heater expansion tankn


Nathan K.

Nathan K. Job Checkin

Installation of 4 new moen 1224 cartridge assemblies, restored water to these faucets and tested for any leaks or drips from the faucet assembly’s, also looked at another faucet in an exam room customer reported water was coming out discolored, ran water for 3-4 minutes with no signs of discoloration, if the faucet is not used often it’s definitely possible the stagnant water within the line could become discolored over time. Running this faucet more often will keep this issue from continuing further


Carlos P.

Carlos P. Job Checkin

Took out the toilet in the women's bathroom and snake it and put 14 cable with the k 50 and flush the toilet and line is clear also flush the men's bathroom toilet and it flush Note going to send a quote for replacing both toilet because is gonna be same issue


Nathan K.

Nathan K. Job Checkin

Attempted to replace hot and cold moen stems in the lab areas, found the cartridges I purchased had larger stop assembly’s, which would not allow these handles to turn on the faucet properly Spoke with service manager about the issue and new cartridges will be located and ordered Noticed when the water was turned back on the faucet seemed to stop dripping, it’s possible some debris or sediment was allowing a small amount of water to pass the gasket and cause a drip Also looked at break room faucet that was spraying from the aerator Found the filter screen was cracked and full of sediment/debris This can cause the aerator to act strange and spray in odd directions Cleared debris and reinstalled aerator, will call Pauline when cartridges arrive