Performed a two system cooling maintenance on a two AirTemp’s the ODT is 67°.Tested overall operation of equipment confirming the indoor & outdoor equipment was both fully operational.There are two 16x25x4 which were gently used with clogging beginning both filters were replaced on this visit.Blower motor was fully operational not showing any signs of being intermittent or dropping out.Blower wheel was inspected finding it to be dirty when a blower wheel gets dirty it minimizes the efficiency of equipment along with places a strain on equipment and parts which shortens the lifespan of both a quote has been provided to clean blower wheel.Inspected indoor evaporator coil finding it to be dirty when a indoor evaporator coil gets dirty it minimizes the efficiency of equipment along with can affect the ability to heat/cool properly a quote has been provided to clean indoor evaporator coil.Inspected wires along with connections not finding any broken, damaged or arced wires along with didn’t