Call to assess and provide quote to get gas lines ran to fireplaces on second floor. Spoke with Ms. Leslie on site and she has already had a fireplace contracting company put, and they have determined the current setup will accommodate a gas fireplace if gas lines are present. I assessed gas system. No issues with gas demand, as the meter and valve can accommodate the two gas fireplaces without requiring an upgrade. Existing appliances include hvac unit in basement, tankless water heater, stovetop, fireplace. I have provided an estimate to install gas lines and rough in for fireplace. While on site I also assessed water pressure, taken at the water heater. The pressure reads ok, but the prv is show in a manufactured date from 2016. The set screw is also almost all the way in, meaning the pressure should likely be a little higher. I don’t believe that the waterline is still galvanized, as I see the old galvanized line entering the home is discontinued. A pex mainline appears to have b