This job replaced the pressure reducing valve with a Zearn NR 3XLPRVW union it is the only PRV that would fit in its space couldn’t use any other without re-typing it. The customer does not have a meter. The water is shut down by the HOA. He does have a shut off valve, but everything is too close to each other to essentially re-pipe it properly so therefore went ahead and installed the double union PRV there’s no leaks set to 65 pounds For replace the shower drain in the master bathroom on the stall install a new P-trap. However it started leaking so I went back with a new solvent, weld PVC 2 inch P-trap and fix the leak by cutting it out and redoing it essentially once that was installed, there’s no leaks. The customer requested to leave the shower great off Because he will be putting on a different one than the one that oatey supplies. At this time, there’s no leaks customers back by one year warranty parts and labor no further issues at this time.