Upon arrival customer stated they were listening the house for sell and list of things they wanted done. Gave customer estimate. Customer approved estimate. I started with the whole hose shut off and prv. I cut out the old ones and installed the new ball valve and prv. While I had the water off I also installed a 1/2 ball valve for a ice maker line and installed a new thermal expansion tank with a mounting bracket . As well as install two stops in the laundry room for the sink they were adding in. I also installed a new hose bib while the water was off. I turned the water back on and tested everything thing and set the pressure to 65 psi. Then I took out old soft copper line for the stove and for the water heater and installed track pipe and two new gas valves. I relight the water heater and make the sure the stove worked. Tested all systems and all systems are working properly with no leaks or issues.