Call for sump pump inspection. Arrived and discussed concerns with Michael on site. He stated that a sump pump was installed in the basement approximately a year ago, in conjunction with other waterproofing and water diversion efforts. He wants to have the pump and system inspected. While inspecting the pump, I found rocks and debris in the basin. No check valve is present on the discharge line. The pump functions normally, and does not appear to be damaged or dis functional in any way. The basin is intact, no cracks, with the exception of intentionally drilled holes for water. While performing routine check of water pressure I found the pressure to be ~80psi at 9am. The pressure regulating valve is extremely corroded. Thermal expansion tank bladder was ruptured, and rusty water was discharged at air port. There is also extreme corrosion along copper lines. I discussed concerns, risks, and solutions with Michael. He has elected to install the Moen Flo automatic leak detection device