Ph8.0 Hardness 5 Psi 82 Arrived on site customer stated that they would like to have a whole home filter installed and a reverse osmosis installed underneath the bar sink. Upon inspection found that we will need to reroute the meter in order to tie in the prv, carbon/water conditioner and then tie back into existing water feed for the house. For the ro system we will be using existing cold faucet and capping off the hot line because customer does not want to drill into the counter tops. Gave options and customer will need some time to research the product before making a decision. Visual diagnostic fee waived. Mail invoice and atlas pamphlet to address