Found the trap was loose and the sealant used on the trap was dry and cracked Allowing this drain assembly to leak Removed trap assembly and reinstalled with new trap sealant Filled sink and ran for appx 10-15 minutes to ensure no further leaks or issues with this drain or piping It’s unlikely that freeing the disposal on the previous visit caused this leak Also looked at customer lobby toilet Found toilet was leaking at the base and needed to be pulled and reset, after pulling found the entire left ear of the flange has broken off and the flange will need to be replaced Cut out flange with saw and chipped away access, set new flange in with glue joint and secured further with tapcons Reset toilet with new wax ring and tested for leaks, could not find any additional issues with this toilet at the time