Found the well tank was working fine, roughly 10 years old and holding air pressure on the top side Ran pump through 3-4 cycles to ensure tank was pressuring and pump was working properly Technician could not find any immediate issues with the well pump, tank, or wiring. Signs of age on the piping may be present however there are no active leaks or failures at the time Water pressure related issue is due to the sediment filters At the time customer mentioned they had decent water pressure at each fixture. However if you ran anything else in the house the pressure would drop. Asked customer when the last time the filter had been replaced and he mentioned it had been at least 6 years Technician believes the sediment filters are packed with debris and causing the issues with the fixtures A full sediment filter can keep water pressure from being allowed to pass through the system Customer also has a culligan system installed, noticed the brine tank was full of water however it’s sta