Remove existing dialectic nipples and corroded fittings to repair leaks. 03/05/2025 Technician repiped side loops on heater. Replaced all corroded fittings coming off of side of heater. Piped T&P discharge pipe from heater to mop sink. Turned off water heater, drained down and piping replacement. Refilled water heater and turned on. Waited for heater to satisfy temp. Went around kitchen and bathroom to bleed air and test for hot water. All fixtures have hot water. Did notice that the 3 comp sink faucet constantly runs if shutoff to spout isn’t off. It’s a T&S brass faucet and requires new cartridges. Also tested the isolation valves / stops for same faucet and neither of them are holding when turned off. Double bowl sink faucet leaks / sprays water from spout connection to faucet body. Faucet would need a new 8 inch spout. Faucet make is Krowne. Check all other sinks and they are working as should at this time.