6178 Energy Road
Bealeton, VA 22712
540-439-6544

Job Locations
for madison, va


Map of Madison VA
Matthew W.

Matthew W.


Job Checkin

Talked with homeowner on what they are needing to pass plumbing inspection. - removal of 5 feet of 4 inch cast iron - reducing existing 4 inch pvc pipe to 3 inch and routing new 3 inch pipe from basement to first floor laundry room. - installation of a 3x2 wye to feed washer box and shower. - new washer box installed, vent for washer box to connect to existing 2 inch DWV copper in same wall. - using existing shower drain and relief venting shower drain, connecting shower vent to existing dwv copper. Shower vent MUST connect to vent 42 inches above floor or 6 inches above the flood level rim of the fixture. Drywall removal may have to occur. We unfortunately do not repair or replace drywall. - work to do done within basement, laundry room and shower stall / room. - testing of work by water test once done. Current inspections to be called in by homeowner and homeowner meeting with county officials for inspection. - we do not warranty existing work done by others.