Ashley B.

Ashley B. Job Checkin

Arrived at location on 4/19/21to service top oven. I turned unit on but it didn't start heating but could smell gas. I found that the ignitor was broken and needs replaced. Will order part. -returned with ignitor. removed front cover, burner manifold and burner tubes. removed ignitor and installed new one. tested operation and unit lit burners and heated up. cycled and all ok.


Service C.

Service C. Job Checkin

Over time - Found Ice Machine bin empty and machine not running. Ice curtain was hung open because the pivot points for the curtain are oblong due to wear. Was able to shim the pivot point and the ice curtain closes properly now. machine made ice and harvested properly. Ice thickness is fine


Service C.

Service C. Job Checkin

Repair left oven door - Came in and removed door to take it back to the shop to work on it. checked out door, bolt broke off so had to drill out and then had to weld holes where spring hooks up to. they are aware. fixed and came back up and put on and checked operation, okay.


Service C.

Service C. Job Checkin

Kitchen Exhaust Fan set screw came out of pulley and slipped belt. Went to hardware store to get new set screw. System is operating properly at this time.


Service C.

Service C. Job Checkin

Found that first Hot Well not heating. found power to the element but element is open. Will obtain element and return. Best time 1-4. 1= SVT423PELEM750 = element 2/3/2020 Replaced left steam table, left well element, tested okay.


Service C.

Service C. Job Checkin

Returned and installed new filter system for Steamer and checked for leaks, all okay.


Service C.

Service C. Job Checkin

Picked up parts, (time included). Replaced supply line from filter system in main kitchen to ice maker. Unit no longer leaking.


Service C.

Service C. Job Checkin

Verified customer concern. Per customer right side is not working. Checked and found element terminals rusted off. Element will need replaced. The model and serial data was worn off of this unit. Contacted Shelly at MFG to attempt to ID table model and part number for element. It appears the Model is a DHT5-208. If that is the correct model a 303173 element will be needed. Looked at pictures of element and it appears to be correct but will need to order and try it. Will order element and return, unit will need new electrical terminals installed there also. 5/31/18 Returned with element Removed defective element and installed new element on first well. Tested unit after installing element, unit has 3.8 amps on each leg. Let heat up and steam . All OK


Service C.

Service C. Job Checkin

Verified customer concern. Found when customer checked unit is was running in defrost. Unit @ temp upon arrival but slightly iced up on right side and motor on right not running. Checked and found evaporator fan motor bad. Replaced right motor. Re set defrost time. Unit working and cooling. Note: defrost @ 2:00 PM so fnas will not be running until defrost ends. Verified pump down and cycle


Service C.

Service C. Job Checkin

Checked range unit & found back burner with poor flame Removed burner & cleaned out inside of burner & top of burner. Adjusted air shutter, all okay. Pilots are almost backed out the whole way to get adjusted properly.


Service C.

Service C. Job Checkin

Removed old unit and installed new Reach-in Cooler. Verified serial and model number