Call for toilet not filling up. Arrived and discussed issues with Mr. Woodward. He states that he noticed the toilet wouldn’t fill up yesterday. Turning the water on and off seemed to get it going quicker for a few seconds. I inspected the toilet and found all components to be very old. The fill valve is not functioning well and seems to be occluded internally. Gaskets all severely deteriorated. Pressure on house approximately 65 psi. Prv appears to have been replaced with two water heaters in 2020. Due to high pressure in neighborhood, significant amounts of construction on on this road, and pressure reading, it may be prudent to upgrade prv to a black tag prv. After checking system, we removed tank and replaced fill valve, flush tower, gaskets and seals. Cleaned under tank and inside tank. Toilet flushing normally and no issues at this time. I discussed signs of pressure issues (squealing noises, vibrations, or water pressure high out of a faucet). If these issues occur please c