Remove existing Prv and furnish and install new 3/4in Prv. Customer stated that they needed previous plumbing repair inspected that was done a few months prior. Couldn’t see the plumbing in the wall but with all visible plumbing everything looks done correctly and doesn’t need an additional repairs. Also Sheetrock was already repaired and customer stated they used fixture multiple times after repair and none of the new Sheetrock feels wet and or have any stains. Also tested water pressure to home and found that it was about 110psi. Stated to customer that water pressure should be at 80 psi and lower and recommend replacing pressure reducing valve. Went ahead and shut water off at the meter and remove existing Prv and installed new one. Turned water back on and pressurized home. Tested work and no leaks were present at this time and also set water pressure to about 60 to 65 psi. Cleaned up work area.