Arrived on site customer stated that they cannot locate the shut off valve for the outdoor shower and hose bib and had multiple people come out and try to locate it. Upon inspection was able to locate a shut off valve that was for the hot side but was not able to locate a shut off valve for the cold or a water line. Searched all over and all I was able to find was 1/2 copper line that capped and went into the ground towards the opposite end of the crawlspace. Recommend installing winterization set up for hot line to blow out be for winter and have access to valve right at the entrance that is more accessible then crawling 50’ into the tiny crawlspace. Also recommend setting a winterization set up for the cold line we are going to install and run all the way to the outdoor shower. We will have to dig approximately 10’ outside of the home install pex in the ground tie in hose bib with new boiler drain and adapt back to existing copper for the outdoor shower. Will include basic shower hea