1833 North Cameron Street
Harrisburg, PA 17103
(717) 236-9039

Job Locations
for malvern, pa


Map of Malvern PA
Service C.

Service C.


Job Checkin

Check found wash element dry fired due to faulty float. Will order new float and element assembly, also wash arm lower is shot. Will obtain parts. 1-31-2017 Dave Spoke to Knowledge Learning Center and got the NTE raid to $925.00 and QWP (expedited freight) charges. 2-2-2017 Removed element. I installed new, replaced wash arm bushing and horizontal float. Tested. No leaks. Ran cycle. OK for use. Did notice element is rated for 230 vac and is supplied with 243 v. Pulling 19 amps instead of 16.