SCOTSMAN ICE MACHINE - 4/6/2021-David W - found unit turned off upon arrival. removed front cover and seen that the light was not on for full sump and water was overfilling. removed water level sensor and found it scaled up. pulled it apart, cleaned it and reassembled. light came in showing full sump now. after the 2nd cycle the water started overflowing again. found water inlet valve was stuck open. will need to order a water inlet solenoid valve and replace. as for now I have machine turned off and water is shut off behind the machine. 04/19/21- Tom-Replaced water inlet valve and ran one batch of ice, Unit is working properly at this time