Michael R.

Michael R. Job Checkin

Clogged drain


Aaron K.

Aaron K. Job Checkin

Thermostat will not allow client to lower temperature, only raise temperature. Determined faulty thermostat. Before replacing thermostat, jumped out system so cooling runs continuously and did a complete evaluation of system. Notice that there is no surge protection on the system, compressor has high startup amps, and is low on refrigerant. Gave client solutions for issues with the system. Client chose solution #1. Replaced thermostat, installed hard start kit to lower compressor startup amps, installed surge protector, and charge system with 2 pounds of refrigerant. Client signed up for annual membership. Cycled and tested system, all operations OK at this time.


Info@masonairconditioning.com

Info@masonairconditioning.com Job Checkin

Brennan G Today I returned and made minor changes to the to the installation. I added a drain line acsess and sealed the air handler platform. I made an attempt to straighten the damaged condenser unit frame. The condenser frame was damaged upon arrival. I informed Mohammed I will speak with a supervisor so we can determine what corrective action must be taken.


Michael S.

Michael S. Job Checkin

Heatpump Electric heater 5kw 35A 10 year parts warranty 1 year labor warranty 1 year maintenance Included in Price: Permits and inspections Warranty registration Removal and disposal of old equipment and materials Labor Taxes Keep existing hurricane pad Refrigerant line flush (rx11) Nitrogen purge brazing procedure Nitrogen pressure test Vaccum test Drain flush Float switches New thermostat Duct sanitation (antimicrobial fog) 50% deposit today Remainder due upon completion


Info@masonairconditioning.com

Info@masonairconditioning.com Job Checkin

Brennan G Today I visited for the system not heating. I discovered the evaporator coil is leaking refrigerant r410 and the system is to low on refrigerant to operate. I provided a repair and replacement quote. Due to the immediate repair costs, future repair costs, and age of the equipment. The repairs of the equipment is not recommended. The system is down at this time.


Info@masonairconditioning.com

Info@masonairconditioning.com Job Checkin

Do not service


Info@masonairconditioning.com

Info@masonairconditioning.com Job Checkin

Brennan G Today I visited for the system not cooling. We discovers the compressor start assist, compressor fan run capacitor and contact relay had failed. We replaced the faulty components and the system is now cooling. 1 year warranty on repairs preformed today. I washed the condenser coil and flushed the drain line with water. I recommended joining our maintenance agreement and preforming a chemical flush of the line. No warranty on drain line.


Brad l.

Brad l. Job Checkin

Furnace Repair: Responding to a homeowner's report of an inconsistent pilot light in their furnace, I conducted a thorough adjustment and cleaning procedure. This meticulous calibration involved assessing the entire pilot assembly, ensuring it remained consistently lit for reliable and uninterrupted heating. The precision adjustment not only addressed the immediate concern but also contributed to the overall safety and efficiency of the furnace system.


Info@masonairconditioning.com

Info@masonairconditioning.com Job Checkin

We finished


Info@masonairconditioning.com

Info@masonairconditioning.com Job Checkin

Duct cleaning estimate