Arrived to find tenets stating mini splits just stopped working. Found bad boards to system and mini splits not communicating. Systems have power but not running. Can not get parts for these off brand systems they are (eBay bought) recommend replacement with branded mini splits for long lasting life span
Arrived to find system set at 66 and was 73 in home. Client stated temp only rose after new coil was installed yesterday. Ran system in charge mode for 30 mins to determine system was never charged properly. Leak searched system to find no signs of a leak. Charged system accordingly and tested. SYSYEM now has a 18 degree temp split with and puking water out drain meaning dehumidification is properly occurring. Client is happy and had concerns on daughter’s bedroom not cooking. Advised duct work was highly recommended but mini split would be a cheaper and more efficient route for that room.
Replaced warranty evap coil
System not cooling adequately, found system low on refrigerant. Performed leak search on system and found leak in evaporator coil. Ordered new coil under warranty. Client responsible for labor. Client paid 50% deposit and returning today to install new coil and 5 pounds of refrigerant.
Brennan G Today I visited for the system making a loud noise when running in the heating mode. I was able to observe the event that was causing the noise. The system would engage into defrost too frequently and the reversing valve pressure shift was loud. I adjusted the defrost timer, heat droop and compressor time delay on the thermostat. I clarified with Alphonso that the system will make this sound on occasion however should only happen when the temperatures outside are very low or when the system turns off in the heating mode. The equipment is operating normally at this time
Arrived to find system set to heat 75 and was 72 inside. Found bad thermostat not send power to system to run Replaced bad t stat under warranty. Made client aware if he is experiencing power surges or power interruption we need to install surge protectors.
Tuneups on Daikin mini split and FIT system
Performed system maintenance.
System charge Incorrect! Adjusted charge to within factory specs. Unit cooling much better now! Schedule a compliments tuneup for September to verify charge is holding and no leaks present! Also recommended portion of attic be sealed up with plastic and plywood so insulation can be upgraded throughout home!
When arrived unit was 74 degrees and 61% humidity. Sealed up all doors and holes on unit and adjusted charge to unit. Thermostat dropped from 81 to 75 when we left with 56% humidity.
Mini split system for garage
Mini split estimate
Found system operating within manufacturer specs. Did suggest to adjust refrigerant in an attempt to better the performance of the system.
Air conditioner Repair - ac trying to engage but fan is not clicking on. so nothings working properly