We had recently installed a customer supplied carbon filter, filtration system in the crawlspace for the client. I arrived today due to the client stating that the crawlspace is flooded and the water is turned off to the home, and the leak is coming from a press connection that we installed. In the entrance of the crawlspace there is about 4in of water by on the other end where the flitration system is, there is about 8in of standing water. Client has a roller on site for me to use to get over to the system to see where the leak is coming from. The leak appears to be on a pro press male adapter that we had installed for the system. Client has set me up with an auxiliary pump they have to begin draining the water out of the crawlspace for me so I can properly make the repair. I cut the piping before the filter, and removed the damaged male adapter. I then supplied and installed new copper pipe and fittings and secured all the connections. Pressed my connections then had the client turn