Arrived, stated left platen left Clamshell grill wasn't turning on yesterday, have error 41. checked error logs, has error 41 a,b, and c. indicating loss of 3 phase power. unit is operating right now. unit likely became unplugged and got reseated when customer cleaned behind unit. did pull unit out and inspect plug and outlet, did make sure connections were tight in plug, on contactor in grill. contactor is OK. check voltage to unit and verify UI is reading the voltage correctly. unit is operational. OK for use.


Service C.

Service C. Job Checkin

checked Cleveland steamer unit, would run for awhile then shut off - pulled side panel bowls are starving for water. tested water pressure from out side of everpure filter system to supply line. has good pressure into filter but very little out. looked on truck for filter ,didn't have in stock. there's no by pass on system. also found filtered water going to condensate. they have their own plumbers but he's in a meeting. explained to chef stewart they need to move inside water line to supply water and change filter. they have ecolab filters they use. let stewart know the reason steamer is not working and that manufacturer won't cover today. unit is down require attention on their end. unit is operational after water pressure problem is fixed.


Service C.

Service C. Job Checkin

Found - Dishwasher machine door guides missing chef wants new set ordered along with spare set. Will order and return to replace. 11/26/19 Follow up - Replaced door guides and gave spares to manager.


Service C.

Service C. Job Checkin

Arrived on site to check Pitco Fryer filter system. checked and found left fryer not actuating filter pump motor when pulling return filter lever. found reed switch behind left fryer drain valve hanging down on one side. screw missing to mount reed switch to mounting bracket. straightened reed switch and tightened existing screw. installed heavy gauge wire in 2nd hole to keep switch from swinging down again. filter pump is now operating for left fryer. filter pan is completely filled with oil, customers responsibility to clean pan out. both fryers operating filter pump. filter system back in operation.


Service C.

Service C. Job Checkin

Installed new curtains and curtain rods and the new rinse thermostat on Dishwasher Pass Through. Found a leak in the weld on the booster tank. Tank needs to be replaced. will get info on replacing it and quote. in service. temps okay. 180 ° + rinse temp .


Service C.

Service C. Job Checkin

Walk in cooler gasket torn, not sealing properly. Gathered info on style and measurements and ordered. 1/14/19 Follow up- Replaced door gasket and checked for proper seal. Note: door expanded due to age, informed manager door may need to be pushed closed until gasket conforms properly.


Service C.

Service C. Job Checkin

Evaporator coil on Reach-In Freezer is iced up, put into defrost, clock is working. Checked heater amp draw both sides of heater pulling name plate amps but one side is hotter then the other.


Service C.

Service C. Job Checkin

Found Vulcan range oven At 25F thermostat 50F too cold at 35F thermostat off 100F. Tried calibrating and adjusting bypass flame will not adjust. Will order new thermostat. 9/7/18 Arrived on site to repair Vulcan range oven. proceeded and replaced left oven thermostat. proceeded to bring range back online. checked top burners.found front center burner off orifice. re-lit all pilots. open top burners, griddle and ovens. checked operation okay. brought left oven into operation to check operation. checked for leaks - none. checked open top burner and griddle operation okay. checked thermostat operation okay. cycles properly and low bypass flame set. double checked right oven operation okay. range oven in service.


Service C.

Service C. Job Checkin

Arrived on-site to check CMA undercounter dishwasher. brought machine into operation to check operation. found chemical corroded rinse roller, hole in pich tube and tubing becoming hard and brittle due to chemical. technician recommends replacing detergent and rinse additive tubing and roller assembly. machine in service. 9/7/18 arrived on-site to repair CMA under-counter dishwasher. replaced detergent and rinse tubing, squeeze tubes and broken elbow fitting. brought dishwasher into operation, primed chemicals, detergent and rinse aid. checked operation of machine very good. tech did notice some water in bottom of machine. looked for any leaks - non apparent. checked all hose connections okay. booster tank looks good, not leaking. checked vacuum breaker and top connections okay - no leakage. possibility of pump motor leaking, but no visual leakage apparent.machine in operation. if water leak is more prevalent, advise replacement of pump motor assembly.


Service Check-In ..

Service Check-In .. Job Checkin

Blodgett commercial kitchen equipment service repair.


Service C.

Service C. Job Checkin

Water pressure gauge leaking. Will quote replacing. 12/26/17 Installed new pressure gauge and tested. 24A @ booster element. 216 vac to unit. Run. Water not leaking at gauge now but another leak is at rear. Found chem fitting missing the plastic nut and fitting fell out causing leak. Used a few nuts from conduit to holds fitting in but still leaks. Not as bad. Will order new fitting. L/M with Lynn 1/9/18 Replaced chemical fitting in back of unit. No leaks. Unit operating properly.


Service C.

Service C. Job Checkin

Blade guard hitting blade. Knife rim guard bracket loose. Tightened and adjusted. Also- blade worn and bent. Cust will replace blade. P/n 460027.


Service C.

Service C. Job Checkin

Power on and loud buzzing noise heard. Pull side cover and found noise is from the fill/drain valve. Removed and installed new. Restarted unit. Now is quiet. Unit fills and hats. 25 amp per element and drying element is 1.3 amp. Total amp is 43-44-44 L1, L2, L3. Power off and drain and restart. It fills and heats. Back to steam. Timer times down and sounds ok. In service. ** Travel Charges billed on WO#138004


Service C.

Service C. Job Checkin

Power supply board transformer melted. Will order power supply board and start/stop board. QWP (Expedited Freight) per Cary Fisher. 6/27/17 Installed upgrade kit and tested. Okay at this time. Unit operational, job complete. Will return power supply to shop.


Service C.

Service C. Job Checkin

Sanitizer pump hose was leaking and the fitting was cracked. Customer gave me parts. I changed the pump housing and cut back the hose. Also, reattached and primed sanitizer. No more leaks. Back in service.