Tenant Stated: She had a rusty/brownish color coming from the fixtures through out the home. Tech Notes: Upon inspection I turned on every fixture through out the home, and was unable to get any discoloration in the water. I ran hot water for 10-15 mins with no brownish coloration or issues. I found that this is a Rheem 50 gallon natural gas water heater located in the garage of home, and was installed back in February of this current year (2024). While on site I checked the whole home water pressure, and received a reading of 140 psi which is outside of state code regulations, and indicates the PRV has failed. I was told by Jamal to contact Sean for replacing the PRV, and never received a response or call back for today’s visit. I did make the tenant aware that this issue must be addressed before further plumbing issues occur to other fixtures through out the home. Resolution: We will need to remove/replace the existing PRV located in the garage of home underneath the water heater