Cut drain in basement. Supplied and installed new pvc pipe and cleanout fitting in the basement for future service of building drain. Adapted to existing copper using no hub connections. Secured connections and ran fixtures in the home to check for leaks. There are no leaks at this time. Supplied and installed new basket strainer for the right bowl on the kitchen sink. Secured those connections and pressure tested sink to check for leaks. There are no leaks at this time. Removed carbon filter and tap on kitchen spread. Installed new sink hole covers and relocated the soap dispenser for the client. *We had recently replaced all the toilets in the home, client states a small leak under one of the toilets. After a full evaluation I discovered that the new shut off valve I supplied appears to be defective with a minor leaks coming from the threads. I replaced the valve and checked for leaks, I then noticed the the 3/8 brass nipple had broke, Replaced the supply line, nipple, and valve fo