Bob S.

Bob S. Job Checkin

Sewer line video camera inspection service call. Televised sewer from clean out in crawl space. Will provide quote to line


Bob S.

Bob S. Job Checkin

Sewer video inspection service call. Televised sewer for possible lining. Clay has a few area with cracks and the cast is slightly scaled.


Bob S.

Bob S. Job Checkin

Sewer inspection service call. Camera inspection & televised sewer from 4” outside clean out 134’ to city main. Customer getting sewer smell upstairs in loft area rarely downstairs. Did a video inspection of the duct work in slab as well.


Josh R.

Josh R. Job Checkin

We are applying the first application of our rubberized duct lining material to all of the heavily rusted underground duct work.


Bob S.

Bob S. Job Checkin

Customer was experiencing no or little air flow in the upstairs master bedroom and bathroom. Used our video camera to inspect the ducts. Found and identified a piece of wood in one of the registers in the bedroom. Located the ducts in the basement and found that two of the ducts had closed bumpers that were hidden behind the drop ceiling. Opened dampers and all airflow was retired to the rooms.


Kevin W.

Kevin W. Job Checkin

We are applying the second application of our rubberized duct lining material to all of the deteriorated underground duct work. The air ducts will be completely sealed and dust and debris will no longer blow out of the air vents.


Kevin W.

Kevin W. Job Checkin

Customer was experiencing sand a debris blowing out of their air vents. We are going to apply two applications of our rubberized duct lining material to completely encapsulate the air ducts. Sand and debris will no longer blow out of the air vents.


Kevin W.

Kevin W. Job Checkin

We are cleaning the underground duct work and applying our duct lining product to the entire underground duct work.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are spiral wound metal. There are ants coming in through the joints in the ducts and also in the plenum that is extremely rusted and deteriorated. Suggest rebuilding the plenum and registers and then spray lining g the ducts with Duct Armor duct lining material in order to seal the joints.


Kevin W.

Kevin W. Job Checkin

Cleaned and spray lined all underground air ducts. Air ducts contained mold from the groundwater inside the ducts.


Bob S.

Bob S. Job Checkin

Video inspection of under slab air ducts. Ducts are spiral wound ducts and are extremely rusted and deteriorated. Suggest restoring structure back to ducts by Trenchless Casting a new concrete duct inside the old ducts. Once the structure is restored then the ducts can be spray lined with Duct Armor to provide a clean healthy breathing environment.

Video inspection of under slab air ducts. Ducts are spiral wound ducts and are extremely rusted and deteriorated. Suggest restoring structure back to ducts by Trenchless Casting a new concrete duct inside the old ducts. Once the structure is restored then the ducts can be spray lined with Duct Armor to provide a clean healthy breathing environment.

Bob S.

Bob S. Job Checkin

Video inspection of underground air ducts. Ducts are rusting and deteriorated. Sump pump does not appear to be operating. Need to replace sump pit then spray line ducts with Duct Armor Duct lining material.


Kevin W.

Kevin W. Job Checkin

We televised a third property with underground duct work for the same customer only to find the duct work was just as bad as the others, this entire system was all metal piping underground that had rusted out completely so we applied our spin cast mortar through the entire system to restructure the metal pipe and applied two applications of the duct armor product to seal the system leaving a clean air flow with no dust or odor from underground ducts!


Kevin W.

Kevin W. Job Checkin

We televised some underground duct work for a customer finding that the pipe was all PVC but the pipe connectors, register boots, and plenum box were all metal and heavily rusted out, so we applied spin cast mortar to restructure the weak rusted metal, rebuilt the register boots and plenum box, finally we applied two applications of the duct armor product to leave an nice clean and sealed HVAC system underground for the fresh air to flow through.


John R.

John R. Job Checkin

Restored and sealed rusted below ground air ducts using spin cast mortar to restore structural integrity of pipe and Duct Armor to seal the ducts.

Restored and sealed rusted below ground air ducts using spin cast mortar to restore structural integrity of pipe and Duct Armor to seal the ducts.