Arrived on the job site and the customer stated that the timer for the Eve outlets was not working properly. Upon inspection, I confirmed the timer was receiving power, but it was not sending power out to the load side. Performed a full troubleshoot, removed the timer, and temporarily bypassed it. All Christmas lights turned on, confirming the issue was either with the timer itself or its installation. I also noticed the circuit was not GFCI protected. I provided pricing and then installed a 2-gang cut-in box, added a GFCI outlet to properly protect the circuit, and rewired the timer. Everything is now operating correctly. Additionally, I replaced the GFCI by the outdoor kitchen in the backyard, which is functioning properly. I also replaced the two-pole 50-amp breaker for the oven in the main panel. The original breaker was a Cutler-Hammer BR; it was replaced with a Siemens 50-amp breaker, which is UL-listed and appropriate for the Siemens panel. All work performed—excluding the ti