Went for an AC inspection today. There was three systems. Changed filters in all three. For all three systems- temperature split between the supply and return duct passed. Evaporator coils are clean and rust free. Blower motor amperage’s passed. Outside systems are clean. Refrigerant pressures met factory specifications. Compressor and fan motor amperage’s passed. Contactors are all working correctly and there is no burn marks. Capacitors passed as well. All ACs are up, running, and cooling upon completion. Thank you for choosing LBA services!