6850 West 47th Tr
Mission, KS 66203
(913) 268-6822

Local Reviews
for overland park, ks

Rated 4.8 out of 5 stars based on 1451 customer reviews

Excellent sey

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Friendly service

Always enjoy him being our service man.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fine

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

He was very courteous and up front on all concerns.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent ser

Great tech

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good job great service

Plumbing inspection- did fine job. Knew about the plumbing

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Tory was very helpful. Not only he fixed the problem he also explained why the problem existed. We are on another schedule to solve the root of the problem.

  • Overall Experience
  • Quality
  • Price
  • Convenience

He was excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent customer service

Great customer care and knowledgeable of equipment.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Joe had knowledge of the equipment. And great customer care.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Patrick at LBA provided me with excellent service today. He is very knowledgeable and thorough. I hope Patrick is recognized for the excellent service that he provided to me today.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Check up

Did a great job explaining what was being done

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Great company

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for overland park, ks

Calvin  W.

Calvin W. Job Checkin

Dispatched for furnace tune-up. The components that are tested during the tuneup are heat exchanger, flame sensor, igniter, blower wheel, inducer, temp split and combustion in the heat exchanger. All components of the furnace are with in range of manufacture specifications. Thank you for allowing us in your house to provide the perfect home service and for being a member of the perfect family service club from your LBA Lead Service tech Calvin. If I provided a positive or five star experience. I’d appreciate you sharing your thoughts in a review.


Andrew S.

Andrew S. Job Checkin

Arrived for furnace check today. System is 2017. Static pressure is good. Heat exchanger looks good. Carbon monoxide test was 0ppm. All electrical is in range. There is a good temperature rise. You have been changing the filters. System is running at departure. Thanks for choosing LBA. Happy Holidays!


Andrew S.

Andrew S. Job Checkin

Arrived for furnace inspection on two systems. Both systems heat exchangers look good. Carbon monoxide tests were 0ppm. All electrical is in range. Filters were replaced today. There are good temperature rises on both. Humidifiers are working. Systems are running at departure. Thanks for choosing LBA. Happy Holidays!


Bradley  L.

Bradley L. Job Checkin

Upon arrival, the customer reported a persistent sewer-gas odor in both the downstairs bathroom and the upstairs bathroom directly above it. They also expressed concern about a possible break in the sewer line. I explained the potential causes of sewer odors and began by running a camera inspection on the downstairs sewer line to check for bellies, breaks, or other abnormalities. Approximately 5 feet from the stack, I found a section of pipe holding water, indicating a slight belly. There was also minor root intrusion at the tap, but neither issue was significant enough to allow sewer gas into the home. The exterior sewer line was inspected as well and was found to be in good overall condition. Next, I inspected the downstairs bathroom where the odor was strongest. Upon opening the shower door, I discovered a large number of dead sewer flies. The shower trap was completely dried out, which will allow sewer gases to enter the home and can also attract sewer flies. I filled the trap with


Fabian C.

Fabian C. Job Checkin

Returned to replace 75 gallon water heater with a 50 gallon water heater. Removed and hauled away old water heater. Installed new BradfordWhite 50 gallon water heater. Installed new expansion tank and shut off for humidifier. Installed new ball valve for water heater and gas shut off as well. Also installed new PRV & shut off valve for the house as well. Checked for leaks and no leaks detected. 6 year water heater tank & parts warranty through manufacture 1 year labor warranty 1 year warranty on PRV & Expansion tank.


Steve R.

Steve R. Job Checkin

12-12-25 The east garage area direct fire heater is not working. Upon arrival, I turned the disconnect on blower motor came on and started humming found the 3 pole disconnect switche bad one leg was not pulling in. I was able to work to switch on and off until all three steps made a good connection you still need to replace this disconnect. Start the system blower motor came on properly thenI was getting a failed ignition module (3 blinks). I was getting 24 V out of the module to the gas valve after tracing the wiring down. I found that the high limit manual safety was tripped. I reset the limit system came on, but also it tripped off again on me. I found the damper wasn’t fully open. I’m pretty sure the damper motor drive motor has failed, currently is it is locked open. At this point, the system is ruuning. we need to get a proposal for the disconnect. There’s still a belt that needs to get replaced and also look in replacing the damper drive motor. See pictures for the Model and


Joe K.

Joe K. Job Checkin

Preformed routine maintenance on furnace. All checks were within manufacturer specifications. Inducer is noisy but not over amping. Blower wheel is slightly dirty


Joe K.

Joe K. Job Checkin

Estimate


Chase P.

Chase P. Job Checkin

Furnace kicked on and ran when I arrived so I performed a three point safety inspection on the furnace. Furnace passed the safety inspection today. I made the system restart and when I restarted the system, I found that the gas valve is working intermittently. I I showed customer pictures and readings I received during the safety inspections. We also talked to options for repair and replacement. Customer would like to take some time to think about which direction they would like to go. I gave them my card in case they have any questions or would like to have us back out. Furnace is working intermittently at departure.


Johann A.

Johann A. Job Checkin

Went for a service call on humidifier. Water panel was dry. Water is coming from shut off valve. Checked solenoid valve and does allow water to flow through. Tech support confirmed of a faulty part, will replace under warranty. System is up and running for humidifier. Water is flowing freely when testing. Thank you for choosing LBA services-Johann


Andrew S.

Andrew S. Job Checkin

Arrived for humidifier not working. Got it wired up to work. No there is hardly any water flowing. Will have to be back again to fix water line.


Fabian C.

Fabian C. Job Checkin

Returned to replace left side water heater. Removed and hauled away old water heater. Installed 50 gallon Bradford White water heater. Installed new shut off valves for humidifiers. Installed new gas line as well. Checked for leaks and no leaks detected. 6 year tank & parts warranty. 1 year labor warranty


Andrew S.

Andrew S. Job Checkin

Arrived for furnace check on two systems. Started on upstairs system and static pressure is ok. Heat exchanger is good. Carbon monoxide test was 0ppm. All electrical is in range. I changed filter and humidifier pad. Blower has some dust build up. The main floor system static pressure is ok. Heat exchanger has some hot spots forming. Carbon monoxide test was 0ppm. All electrical is in range. I changed filter and humidifier pad. Both humidifiers are working properly. Systems are running at departure. Thanks for choosing LBA. Happy holidays!


Joe K.

Joe K. Job Checkin

Removed 2" and replaced with 3".


Patrick  K.

Patrick K. Job Checkin

Approved estimates over the phone