6850 West 47th Tr
Mission, KS 66203

Local Reviews
for overland park, ks

Rated 4.9 out of 5 stars based on 720 customer reviews

Outstanding Customer Service

Andrew was extremely knowledgeable and respectful.

  • Overall Experience
  • Quality
  • Price
  • Convenience

All went good...

  • Overall Experience
  • Quality
  • Price
  • Convenience

Justin Montez

Justin Montez was the best person you have ever sent my way!! Want him every time!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service

The technician get a great job of calling me and explaing everything. I went into detail about everything that was done or anything he recommended. Five star

  • Overall Experience
  • Quality
  • Price
  • Convenience

Right on time!

They’re my go to HVAC guys / gals

  • Overall Experience
  • Quality
  • Price
  • Convenience

Immediate Sunday morning repair service to put furnace back in service on a cold (low 20's) morning !

We woke up to a very cold home due to a malfunctioning Lennox heating unit that was 5 years old. Approximately two hours after I placed the trouble call to LBA a repairman was at my front door which was an excellent response. I chose to deploy the Platinum service offered by LBA along with a warranty replacement on a pressure switch. We were up and running by mid afternoon before the start of the Chiefs/Texans playoff game at Arrowhead.

  • Overall Experience
  • Quality
  • Price
  • Convenience

New technician, same great service

Estuardo came to check my furnace today, and like all the other technicians from LBA, he was great! Friendly, efficient, and obviously knows what he is doing. I am so happy I chose LBA when I had my furnace replaced, they are all wonderful to do business with!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Friendly, thorough, quality service

I got a “heads up” phone call when the service tech was in transit to my home. He arrived when he was expected and worked diligently until done. He was thorough in his work, reviewed his findings with me and made sure I understood both the issues uncovered and my options for addressing them. He made earnest recommendations, but I never felt pressured to purchase the most expensive fix.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Another Great Service Call

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

LBA has qualified professionals who are polite and know what they’re doing.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for overland park, ks

Phil N.

Phil N. Job Checkin

After calling customer. They decided to call back Monday.


Andrew  G.

Andrew G. Job Checkin

I performed a safety and maintenance inspection on the Lennox SL280 furnace system. During my inspection I discovered that the inducer has a possible leak at the seam between the outlet and flue piping but there was no active leak at this time and a picture is included for reference. Also, the inducer VEC tested right at tolerance. I informed the customer that the VEC will likely need to be replaced next year. Additionally, the customer purchased a tune up on the humidifier and renewed their P3 membership choosing the annual recurring standard P3 option. The customer also has a Sanuvox UV Sabre bulb but didn’t want to replace the bulb and didn’t show interest in maintaining that equipment at this time. Thank you


Nathaniel  R.

Nathaniel R. Job Checkin

Couldn’t get the clog out and having Justin come out to try to get the clog out of the shower tub. Not collecting any money do to the job not being complete.


Justin M.

Justin M. Job Checkin

Upon arrival navien water heater set to 160 deg. Was not keeping up with hot water output to dishwasher as shown the dishwashers temperature display. Checked lines and settings and determined internal check valve had failed allowing cold water to back feed into return line. Replaced check valve. Difference of about 15-20 degrees were produced from water heater. Dishwasher display screen would still intermittently show a low temperature notification. After much testing it was noticed that a delay or stutter would happen occasionally at the dishwasher when calling for water. This causes excess cold water to come into the line by delaying the heaters heating process and lowers the output temperature. Recommend dishwasher functions be assessed. Recirculation line isolation valve added for testing and by pass purposes


Andrew  G.

Andrew G. Job Checkin

I performed a safety and maintenance inspection on the Ruud UO6VA furnace system. I found the furnace system to be operating within the manufacturers tolerances at this time. Additionally, the customer purchased a humidifier tuneup as well as renewing their P3 membership. The customer chose the annual recurring standard P3 membership option. I also spoke with the customer about changing their air filter more frequently to extend the life of their new equipment. Thank you


Scott w.

Scott w. Job Checkin

Arrived on site to address lack of heat in dining area. Manager on site thought the units were now working. Upon investigation of units, RTUs 2&3 heating modes were locked out due to too many attempts for heat with no flame proofed. Units were firing properly, but the flame sense rods were reading 0 and <1 mADC after cleaning them. The flame rods must be replaced in order for the units to provide heat. There currently are no flame rods (Lennox P/N: 49M84) in the metro area for these units. The sensors must be ordered and expected delivery, if ordered now, is next Monday/Tuesday. Please see accompanying repair proposal for details.


Jerry B.

Jerry B. Job Checkin

Replace the 150-40 limit switch and 10 mfd blower capacitor We replace the blower motor capacitor in the high limit safety switch and then tested the system in heat mode, allowing it to run for 15 minutes. The system never turned off and is running properly at this time.


Rick B.

Rick B. Job Checkin

Quoted requested repairs for the Engineered Air make up. Emailed the quote to the contact listed in the workorder.


Andrew  G.

Andrew G. Job Checkin

Upon arrival, the customer informed me that the Payne PG9MAA furnace system wasn’t operating and the fault code displayed was 31. After further investigations, I discovered a fault within the combustion pressure sensing system. The pressure switch was failing to close when the inducer motor was operating. I cleaned all tubing and ports and the system is now temporarily operational. The problem is likely to reoccur unless repairs are made. I recommended to the customer that we replace the pressure switch and all barometric tubing with the bronze level HM11B basic combustion pressure sensing system renovation repair option which I have included an estimate for. I also found there to be corrosion or possible water damage to the IFC board and I have included a picture for reference. The customer stated that they will be selling the residence in the next few months so at this time they are not interested in equipment replacement. The customer also stated that they will likely call tomorro


Eli M.

Eli M. Job Checkin

Today I completed your annual heating tune up, I checked all safety and electrical devices to ensure your system is running safely and efficiently, I cleaned system and performed combustion analysis, checked for proper heating transfer, everything tested as it should at this time, thanks for choosing Lba, Eli


Phil N.

Phil N. Job Checkin

Water piping making noise. After inspection found the water pressure on newly installed pressure reducing valve was elevated . Adjusted pressure valve. And checked operation. Warranty no charge.


Gary P.

Gary P. Job Checkin

Create estimate for Greg


Estuardo V.

Estuardo V. Job Checkin

Performed a restriction evaluation, Minimal airflow in certain rooms of basemen. Performed a CFM supply reading in the rooms adjusted restriction and each supply in basement reading 110° through supply line . The rooms are heating properly and tested out great. Customer is happy. Would like A water softener estimate.


Chris S.

Chris S. Job Checkin

Installed 800 April aire steam humidifier


Rick B.

Rick B. Job Checkin

Checked the Lennox Rtu serial 5612H00719 for no heat complaint. Found the flame rollout switch tripped. Inspected the exchanger and found no rust out or cracks. Pulled the inducer assembly and checked for a blockage. Found part of a old wasp nest in the inducer outlet causing a slight restriction. Cleaned the outlet and tested the unit in heat. Noted to the customer that the heat exchanger has a slight soot build up from the restriction that should clean up from normal use. If the rollout switch trips again the heat exchanger will need replacing.