Plumbing inspection- did fine job. Knew about the plumbing
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Tory was very helpful. Not only he fixed the problem he also explained why the problem existed. We are on another schedule to solve the root of the problem.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Great customer care and knowledgeable of equipment.
Overall Experience
Quality
Price
Convenience
Joe had knowledge of the equipment. And great customer care.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Patrick at LBA provided me with excellent service today. He is very knowledgeable and thorough. I hope Patrick is recognized for the excellent service that he provided to me today.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Arrived for furnace out. Found flame sensor was dirty, cleaned it and started system. System ran for 30 minutes with no issue. Today you signed up on our membership. We will be reaching out to set an appointment for a full system check. Thanks you!
Full system sold for Friday 96% , 100k btu dual stage furnace 14 seer 4 ton a/c coil 14x24x4 return drop and furnace base can Eco bee
Arrived for furnace out. Tried to replace blower motor with universal. It did not work. We are bringing our space heaters for you. Possibly replacement talk. Thanks for choosing LBA
Quote to replace the (2) heat exchangers for first and second stage heat in the Lennox package unit serial 5609D00071 marked as #6 for the Sanctuary. Price includes the factory replacement parts, crane rental and labor. Repairs covered by a one year parts and labor warranty. Price is for the listed repairs only. The unit will be thoroughly tested in heat mode after repairs. Any further repairs if required will be quoted to the customer separately.
Arrived to do a performance maintenance. Set up for combustion analysis temperature split and static pressure tests. Found that the system is operating just above the maximum rated static pressure. Verified operation of all mechanical and electronic components of the furnace. Checked blower for cleanliness and to see if there is any play in the bearings. Found that the fan for heating and cooling is coated in dust debris. Checked systems heat exchanger to ensure proper venting of flue gas. While checking the heat exchanger found bacterial growth present on the bottom of the evaporator pan. Verified operation of the humidifier. Furnace and humidifier are operational at this time.
Checked the package unit s/n 0336. Found that this system is in bad shape due to lack of maintenance. It needs a condenser fan motor, capacitor, blower motor belt, filters, and a deep cleaning on the system. Sent info to rick and sent an estimate for repairs and replacement do to the age of this unit. Note: there were two other HVAC companies on site looking at the same unit while I was on site.
Arrived to replace roll out switch. Started heat mode and system is running properly. There is a good temperature rise. Thanks for choosing LBA.
Completed furnace, maintenance and inspection. I cleaned flame sensor and wiped down furnace. I checked amp draws and tested components. I tested airflow and temp splits. Air filter does need changed out soon. I flipped the humidifier pad upside up. I found bacterial growth on the water pan for the indoor coil. Furnace is operating within manufacturer specifications at departure.
Completed furnace, maintenance and inspection. I cleaned flame sensor and wiped down furnace. I checked amp draws and tested components. I tested airflow and temp splits. Air filter does need changed out soon. I flipped the humidifier pad upside up. I found bacterial growth on the water pan for the indoor coil. Furnace is operating within manufacturer specifications at departure. I talked with customer about the bacterial growth on the coil area. We scheduled a duct cleaning with a UV system for next week on Wednesday morning.
I dismissed the Z wave alert on the thermostat, which is for the Wi-Fi set up of it. On the furnace I found a rollout switch that has gone faulty. Distributors are closed till Monday so on Monday morning I will order the part and then we will need to return to install the new rollout switch.
Customer called in about toilet in main floor hallway leaking from the base. Flushed toilet and started leaking from the left side. Confirmed that we need to replace wax ring. Customer purchased toilet from us a few years ago. Gave customer couple of different options. Explained if the first option won’t work, we will move to second option. Customer agreed to both prices. Went ahead and pulled toilet and confirmed we need to raise toilet flange. Went ahead and performed flange repair kits to raise the flange to meet with floor. Installed new wax ring and reset toilet. Toilet no longer moves. Flushed toilet multiple times and no signs of leak.
Completed furnace, maintenance and inspection. I cleaned flame sensor and wiped down furnace. I checked amp draws and components. I tested airflow and temp splits. Humidifier has been disconnected. Air filter looks good. I checked condensation lines and air tubes. Furnace is operating within manufacture specifications at departure.
*)*)*)*)*)*)*)*)*)) Used qty 2 adjustable elbows 6” from warehouse. Qty 3’ single wall flue pipe from warehouse Gas valve cd jones (gas valve was $15 more than original quote for the valve). But didn’t use 6-8 reducer as planned, Thermocouple from truck (Tom gave me a few the other day) *))*)*)**)*)*)*)*)*)*)*)*)*)***)*)*)&)&)&)&))&)&&)&)&))&&))&))*)*) Today the furnace that serves the conference room and offices was repaired by installing a new gas valve and replacing the flue pipe sections that are rusting through. The heat exchanger was checked using a match test, visual inspection and a combustion analysis. The vent motor was checked for bearing wear and confirmed that the sail switch is wired in and does shut down the burners if the motor quits functioning. The burners were removed, wire brushed and reinstalled, The pilot assembly was cleaned and a new thermocouple was installed. Gas pressure is in range and the flames were visually checked. The combustion analysis f
Furnace control board still had power and three amp fuse was not popped. Thermostat did not have batteries inside it as a back of power so we put batteries in and thermostat turned on and ran furnace as it should. After talking with customer, they will decide if they want to replace the thermostat or not. I told them if they would like to replace it then to just give us a call and we can get someone out to do that.