6850 West 47th Tr
Mission, KS 66203
(913) 268-6822

Local Reviews
for grain valley, mo

Rated 5.0 out of 5 stars based on 3 customer reviews

Great service

David was very informative and help point us in the right direction. Waylon was also very helpful and helping us through an issue we were having.

  • Overall Experience
  • Quality
  • Price
  • Convenience

A very fine and courteous crew.

I love My new furnace and air conditioning.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great response and professionalism

I was impressed with the professionalism and response. The technician was well manered and very informative. I will be using LBA for my repairs in the future.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for grain valley, mo

David W.

David W. Job Checkin

Upon arrival turned main water off at metered pit in order to install new ball valve, and bypass system for new Halo 2 mini. After draining the system, cut out existing PRV and lowered, then created loop and a by pass system then installed new Halo 2 Mini, install new ball valves on inlet and outlet side of filter. Tested for leaks by turning main water back on at meter pit, then aired out water lines by running water through all fixtures. All good no leaks and all fixtures are working properly.


David W.

David W. Job Checkin

Polyphosphate Filter , 2x Toilet Upon arrival, drained disconnected and pulled toilet in hallway bath, as well as in master bath. Removed both toilets and installed new Elongated ADA Comfort height toilets both installed with new wax ring, bolts and supply lines. Tested for leaks by flushing both toilets multiple times, all good no leaks present. Will come back to install new Halo 2 Mini Filtration.


jamal.allen@lbaservices.com

jamal.allen@lbaservices.com Job Checkin

Will be calling customer tomorrow for verbal agreement on financing with Eric and Waylan. Thank you for choosing LBA.


Scott M.

Scott M. Job Checkin

During main customer passed static test but failed cfm test customer isn’t interested in a solution. Checked out the rest of the furnace everything else looks good nothing in need of attention


Nabatae A.

Nabatae A. Job Checkin

Furnace maintenance CO readings 0PPM, cleaned flame sensor, inspected burner compartment, inspected gas valve and pressures, inspected flue pipe, inspected draft inducer motor, inspected limits and safeties, checked all electrical connections, inspected pressure, switch, inspected heat exchanger, inspected blower wheel and blower motor, inspected circuitboard, tested amp draws, checked filter, cycled unit for proper operation


Patrick  K.

Patrick K. Job Checkin

Arrived to do a performance maintenance. Started inspection outside and verified system refrigerant charge. Verified operation of all mechanical and electronic components of the condenser. Found that the condenser capacitor is performing well outside factory specifications. Moved inspection inside and measured a temperature split between return and supply air. Measured power consumption of the blower motor and checked system for cleanliness. Found that the blower wheel is heavily coated in dust and debris. Performed a static pressure test and found that the system was operating well outside the rated maximum static pressure. System is rated for .8 static pressure and is performing at 1.3. This is going to cause the system to wear and tear faster. With homeowners approval reached out and scheduled a supervisor visit for tomorrow afternoon. The supervisor will be able to assess the system and determine the cause of the systems high static pressure. With homeowners approval replaced the f


Patrick  K.

Patrick K. Job Checkin

Arrived to do a performance maintenance. Started inspection outside and verified system refrigerant charge. Verified operation of all mechanical and electronic components of the condenser. Moved inspection inside and measured a temperature split between return and supply air. Measured power consumption of the blower motor and checked system for cleanliness. Performed a static pressure test and found that the system was operating well outside the rated maximum static pressure. Spoke with supervisor for solutions I can perform to rectify the systems static pressure. With homeowners approval reached out to a supervisor to provide a diagnosis on the systems high static pressure. Removed the filter from the system to relieve as much static pressure as possible until the supervisor can provide the diagnosis. Air conditioning system is functioning at this time.


Daniel A.

Daniel A. Job Checkin

Drop off delivery of filter 16 x 20 x 1.


Daniel A.

Daniel A. Job Checkin

Heating maintenance. Checked all task. Everything well within range. Recommended new pack of 16 x 20 dynamic filters for customer. Customer excepted. Made sure system ran before leaving.


Daniel A.

Daniel A. Job Checkin

Installed a prayer bypass 600 humidifier. Made sure system ran before leaving


Alex H.

Alex H. Job Checkin

Perform a heating maintenance checked all operations checked blower motor inducer motor checked all electrical components check temperature split check drain lines replace filter provided by customer check seal levels check heat exchanger clean flame sensor check igniter system is running with the manufacture specifications thank you for having me out today Alex View visual findings from this job here - https://visionshare.xoi.io/?id=XA-7A3A-DDDCCDB1E705411D944A1F24AE7CE1A7