6850 West 47th Tr
Mission, KS 66203
(913) 268-6822

Local Reviews
for gladstone, mo

Rated 4.8 out of 5 stars based on 56 customer reviews

Excellent service


Response from LBA Air Conditioning, Heating & Plumbing:

We count ourselves lucky for customers like you and look forward to working with you again in the future!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Took care of problem very quickly

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

He did an excellent job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Kaden did a good job in shorter time than we expected tgx

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

He worked hard to find problem did wel

  • Overall Experience
  • Quality
  • Price
  • Convenience

Did good job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thank you...

Corbin was on time, courteous and informative.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for gladstone, mo

Tj M.

Tj M. Job Checkin

Needs to speak to partner about the financial


Jason S.

Jason S. Job Checkin

Gave options for shut off valve new faucet and stack replacement


Richard H.

Richard H. Job Checkin

Installed 2 bay returned on staircase ran an 8 inches also installed a bypass damper and register


jamal.allen@lbaservices.com

jamal.allen@lbaservices.com Job Checkin

Spoke with the customer about water quality and the failed pressure regulator valve. Thank you for choosing LBA.


Scott M.

Scott M. Job Checkin

Sold


Jason S.

Jason S. Job Checkin

Did inspection


Tyler R.

Tyler R. Job Checkin

Upon arrival I began the furnace maintenance. The static pressure was rated for a .5 max and it was reading at .4 which is 80% of the max. Heating Delta T was at 57 degrees which is within manufacturer specifications. Checked all electrical components and they were within specs. The cooling delta t was at 20 degrees which is also within specs. The outdoor unit was within specs on all electrical components. The refrigerant charge looked good and the system is running properly at this time.


Robert S.

Robert S. Job Checkin

Checked all operations in the heating and cooling modes. Inspected furnace filter and found the pure air kit was in need of replacement. Checked static and found it was passing. Checked all electrical and refrigerant components. Today we found the condenser fan was leaking oil, and the contractor was burnt. Upon customer approval we reported the contactor and pure air kit. System is operating properly.


Scott M.

Scott M. Job Checkin

Na


Sagan H.

Sagan H. Job Checkin

Retested and discussed readings


Cesar A.

Cesar A. Job Checkin

Performed annual plumbing inspection. During inspection noticed that water pressure is higher than it should be indicating failed pressure regulating valve. Main entrance valve also shows signs of intermittent leaking. Primary sump pump is approximately 10 years old. Secondary sump pump is approximately seven years old. Based on age replacement of both pumps recommended as preventative maintenance.


Jesse R.

Jesse R. Job Checkin

Company will come out and cut up concrete at marked location and dig hole down to mainline and replace up to 10 foot section of drain line. Refill hole and repour concrete.


Aaron K.

Aaron K. Job Checkin

Air Conditioning System Tune-Up: A customer reported reduced cooling efficiency and strange noises. Our diagnosis revealed a refrigerant leak affecting the compressor. We repaired the leak, recharged the refrigerant, and fine-tuned the system for optimal performance. Regular air conditioning tune-ups were advised to detect and address issues proactively.


Adrian C.

Adrian C. Job Checkin

Arrived at property he was greeted by homeowner, mainline was backed up on arrival and the drain tech was unable to get line open. Drain text cable snapped off inside of mainline. Upon camera inspection I was able to get my cable out to about 40 feet, but I was not able to see anything due to the line being full of water. Marked location where my camera stopped and provided estimate for spot repair. Customer signed off on estimate and is scheduled for Wednesday morning install February 28.


Cesar A.

Cesar A. Job Checkin

Reached out to customer to discuss water heater and water pressure estimates. Did not get a response.