The clogged sink was unclogged but the drain it went to was backed up. He told me it was fixed and left but it overflows when I use the dishwasher or washing machine. He left a bunch of dirt in the sink he unclogged and he dumped the sludge water that came out into my basement toilet. When I asked him about it he said it’s fine the opening in the toilet is bigger than the sink pipe. Common sense would tell you to dump the water outside and not in a place it could cause another issue. I will not use you guys again, sorry.
Response from LBA Air Conditioning, Heating & Plumbing:
We count ourselves lucky for customers like you and look forward to working with you again in the future!
Completed AC inspection for customer. All aspects of system tested within manufacturer specifications. No recommendations at this time. Thank you!
Went for a maintenance call today. Tested for static pressure, system is at max rating. All electrical components are passing for manufacture specifications. Temp split is passing and as well, for refrigerant. Cleaned condenser unit and replaced filter. No further wear and tear. Thank you for choosing LBA services-Johann
Dispatched to add refrigerant that another company installed. At arrival I tested the AC system and my pressures indicated that it was super low refrigerant. After performing a recovery and a leak test, I discovered the leak at the bolt for the orifice. Tightened the orifices bolt down and confirmed there was no leak. After the leak test, I pulled a vacuum and charge the system with 5.1lbs. Tested the system and is performing at manufacture specs. Thank you for choosing LBA services.
Will follow up once pricing received from A1.
Arrived to install smart ac sensors and set up the app on the homeowners phone. Set up the hub and connected it to the house Wi-Fi. Connected each sensor to the hub and set them in their assorted locations throughout the system. Set up the app on homeowners phone and ran through the various functions of the app. System is functioning properly at this time.
80%, 80k btu furnace , 3 ton 14 seer ac/coil sold for tomorrow
Customer ready to move forward. Needs to get cosigner for financing. Will follow up 3/25/25.
Arrived to verify a systems need for replacement. Spoke with the homeowner and gathered that there is an internal failure in the compressor. Tested the windings of the compressor and found them failed. Tested to see if the compressor is shorted to ground and unfortunately it is. The heart of the air conditioner is completely failed. Inspected the furnace to ensure that once the ac is repaired or replaced that the system will be able to continue to operate without issue. Found that the furnace fan takes a while to get up to speed, and is making a droning noise while trying to get to speed. Tested the systems airflow and found that the system is operating with failing static pressure. Relayed all information to the field supervisor to build different estimates for different options to address the different issues. Breaker to the ac is left in the off position. Furnace is operational upon departure. Thanks for the cards!
Customer had quote for 2k for compressor replacement and 5k for an a/c install. He is not going to use us
Completed cooling maintenance. Checked amp draw on blower motor and compressor, checked bearings on blower motor and condenser fan motor, cleaned coil, changed filters, checked contactor,checked temp split, unit is functioning properly at this time