6850 West 47th Tr
Mission, KS 66203

Local Reviews
for stilwell, ks

Rated 5.0 out of 5 stars based on 22 customer reviews

Great service

Aaron did a very thorough job and explained everything perfectly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Would recommend them to anyone. They are friendly knowledgeable patient & efficient.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic fast, friendly service on Christmas Eve, but very high price compared to the competition.

There was a tech at our door less than 2 hours after we contacted the company on Christmas Eve regarding our hot water heater going out with 12 people staying at our home. He was friendly, knowledgable and fast. However, the pricing was much higher than other companies.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic Customer Service and Price

LBA has taken great care of our needs since day one when they installed our system and today was no different. Any project that is beyond my abilities, the will be my first call.

  • Overall Experience
  • Quality
  • Price
  • Convenience

AC Maintenance

Rigo did a great job answering my questions and completing the job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great company to do business with.

LBA has always answered our SOS's promptly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Thanks for being on time, efficient and helpful!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Pricey but good service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Aaron was great!

Aaron was very efficient, timely and helpful in regards to serving our furnace today.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always on time

Aaron was on time, professional and did a great job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for stilwell, ks

Nathaniel  R.

Nathaniel R. Job Checkin

I preformed a plumbing inspection.


Andrew  G.

Andrew G. Job Checkin

Upon arrival the customer informed me that the furnace wasn’t blowing hot air and also the outdoor condenser fan was running and making a weird noise. After further investigations I discovered that there was a fault within the control wiring. I inquired about the nest thermostat as to when it was installed and by whom and the customer told me that they had a family member install it for them. I presented repair options to the customer and the customer chose the band aid level voltage conversion system rejuvenation. After completing the repair, I checked to make sure the system would operate the appropriate components when called for and the system functioned as it should. Additionally, I instructed the customer to keep an eye on the furnace over the next couple of hours as the evaporator coil thawed. I told them that the water from the ice melting should all come out through the condensation drain line but just in case some water comes out elsewhere, it is best to wipe it up periodic


Kevin M.

Kevin M. Job Checkin

Gas line for pool heater


Andrew  G.

Andrew G. Job Checkin

***cleaned leaves out of fresh air intake of furnace*** ***humidifier solenoid valve fault*** I performed a safety and maintenance inspection on the furnace unit. At this time I found everything to be operating within the manufacturers tolerances. The customer also purchased a humidifier tuneup at which time I discovered a fault within the moisture restoration system valve. The valve was clogged up with minerals and other deposits that are in the water and wouldn’t allow the water to come out when called for. I presented repair options to the customer and the customer chose the band aid level HH7A moisture restoration system rejuvenation repair. After completing the repair the moisture restoration system was operating as it should. Thank you


Pat M.

Pat M. Job Checkin

Estimate for gas line


Pat M.

Pat M. Job Checkin

Estimate for new water heater


Nick S.

Nick S. Job Checkin

Checked all operations in the heating mode. Performed a combustion analysis as well as checking carbon and oxygen levels. Cleaned off blower wheel as well as the furnace itself. Changed filter with customer supplied filter. System is operating within factory specifications at this time.


Nick S.

Nick S. Job Checkin

Checked all operations in the heating mode. Performed a combustion analysis as well as checking carbon and oxygen levels. Cleaned off blower wheel as well as the furnace itself. Changed furnace filter with customer provided filter. Spoke with customer about joining P3 agreement which they did not want to do so at this time. System is operating within factory specifications at this time. Very nice meeting and talking to you


Aaron R.

Aaron R. Job Checkin

I conducted a performance and safety inspection for the furnace. During the inspection, I found that the humidifier is not operational. I found that the water shut off for the water supply and the water isolation control valve is not functioning. I emailed the customer repair options to repair the humidifier and I also emailed replacement options to replace a humidifier. The is operating properly and safely within factory specifications.


Jerry B.

Jerry B. Job Checkin

I arrived to find the whole home dehumidifier locked out to error code E2, high refrigerant pressure. I checked the filter and it looked clean but I cleaned it anyway. I then checked to make sure the fan motor works and there was nothing obstructing it or the air flow. I the reset the system and it has been working properly since. The humidity was at 60% and has dropped to 54% since it has been running. I have spoke with the manufacturer and they believes it to be related recent storms.


Andrew  G.

Andrew G. Job Checkin

Upon arrival the resident described to me that the air conditioner was leaking water. After further investigations I found that the condensate line had a blockage that wasn’t allowing the water to escape to the floor drain but it was coming out of the furnace secondary condensation drain connection instead. I made a band aid level repair to the condensate line by the use of nitrogen and flushing with hot water. I did waive the $59 trip charge due the ease of the repair. Thank you


Nick L.

Nick L. Job Checkin

Checked all operations in the cooling mode. Replaced furnace filter. Washed out the outdoor unit. Found a rodent living inside of the outdoor unit no damage was visible at this time rodent had Peed on electrical parts which can reduce the lifespan of the parts. System is cooling properly at this time.


Aaron R.

Aaron R. Job Checkin

Arrived to find that the set screw for the blower wheel had fallen off and the blower wheel was rubbing against the blower housing. I reset the blower wheel and tighten the set screw. The system is now operating properly at this time.


Jerry B.

Jerry B. Job Checkin

The upstairs is still having issues staying cool. I adjusted the dampers and there is plenty of airflow coming or of the upstairs vents. I also have a proper temperature split. I believe the issue is related to insulation of the roof and attic. The Fox family is having someone come out to see what they can do about insulation.


Aaron R.

Aaron R. Job Checkin

I conducted a performance and safety inspection for the air-conditioner. I found that the outdoor coil was completely plugged with cotton and dirt. I chemical wash outdoor coil to maintain the systems performance and efficiency during peak demand times.