Very kind and thoughtful. Did a great job and cleaned everything up afterwards.
Very professional and helpful. Explained everything in detail so I would understand. I felt very good with his service.
The entire team at LBA went above and beyond to help me after we had a water pipe rupture this winter. I can’t thank them enough! Truly wonderful service and team!
Arrived on time, was respectful of home, efficient in doing work, fixed the problem. Thanks!
I had to make an emergency call when I found water on and around my furnace/ac unit. Adam came out right away and was so polite and helpful. I really appreciated his approach - it helped relieve a lot of stress.
Quote to replace the heat exchanger in the West Trane package unit serial 154912350L marked as #1. Price includes the factory replacement heat exchanger, shipping and labor. Repairs covered by a one year parts and labor warranty. The existing heat exchanger is rusted through at the seams. The unit has the heat mode disabled for safety until repairs are made.
Today two rooftop units and a split system had maintenance and heating checks performed. The filters were changed and the heating functions were checked. The rooftop unit on the west has a heat exchanger that is breached. The gas was turned off to the unit at the roof for safety. Information was gathered for a heat exchanger replacement estimate. All three units checked today passed all heating tests and inspection. Thank you, Jon
Installed new r/a drop an added two 8x30 r/a’s
Sold discounted ductwork job due to needing to be upsized in the first place and recent install. Plus we’ve already had a blower motor failure. $2675 installing 7/24 paying with check.
Went for a service call today. Blower motor wasn’t coming on. I noticed it had burn marks on the module. After bypassing the board to turn the motor on it still wasn’t coming on. I replaced the motor and system is up and running. Thank you for choosing LBA services!
For this job we did a tankless water heater flush and replaced a check valve inside navien tankless. Hot water back to normal
Tankless water heater needs a new check valve and water heater flush
Capacitor was replaced and condenser coil was cleaned. Systems charge is within specifications at this time
Went for a tune up, system is failing when testing for static pressure for cool. Capacitor is failing for system. Fan motor is running close to max rating. Refrigerant pressure are within range. Did clean condenser unit. As well replaced filter. Temp split is passing for system. Compressor and blower motor amperage are passing. System is up and running before leaving.
6/13/25 - Completed a full cooling maintenance on all equipment. The filters were changed, the coils were cleaned, and proper operation was tested. Overall, all equipment was in good condition, it was all running as it should be, and there were no issues found at this time.
Completed ac inspection. All components tested to manufacture specifications. Had some issues with the membership but we got that all figured out while I was here