Knowledgeable technicians who price repair work fairly. Excellent customer service on the Office side. Highly recommend them.
Knowledgeable, prompt, courteous, easy to work with. Also, believe quoted pricing is very fair.
I am so glad I selected LBA to do the work for my sewer problem!
Explained all options. Cameron was pleasant and answered all questions, even repeated ones. He was very helpful. Glad I contacted LBA.
Cesar was extremely professional and extraordinary polite while completing a small but very challenging project for us. LBA promptly returned calls and scheduled our work when we needed it done. I continue to recommend their quality service.
Knowledgeable, professional, and timely. Great service and interested in helping customers. They have our repeat business in the future!
Joseph was very straightforward and knowledgeable. His sense of humor was delightful. I felt very comfortable with him in my house
Arrived for code on thermostat. Code was E79, no power to C wire. Pulled stat off wall and found that thence wore was not fully connected. Connected wire and power is to wire. Thermostat is working properly. System is running and cooling properly. No charge for today. Thanks for choosing LBA.
-Installed customer supplied pop-up drain assembly in master bath lavatory sink -Tested and no leaks Thanks for choosing LBA Services! Jeremy
doing maintenance on an HVAC system, I fixed a flex duct that was coming apart in the garage leading up into the attic. Also left a spare filter and cleaned out the unit. Everything is running great at this time however we had some plumbing questions so I called one of our plumbing supervisors to come out and look at the plumbing. Thank you for choosing LBA! Welcome to the club! - Walker
Arrived for ac no cool. Upon arrival there was no power at furnace. I found that the fuse had pooped. I then found a loose wire that had caused the fuse to pop. Tightened wire up, replaced fuse, and system started up. While I was there I did a check on the whole system. All components of the system are running how they should. I cycled system a couple times to make sure it shut down and started as it should. System is running upon departure. Don’t forget to call and sign up for membership! Thanks for choosing LBA.
Arrived for ac check on two systems. Started on main floor system and checked static pressure, it is failing running at twice the max. Blower wheel is dirty. Motor amps were good. There was a 17 degree temperature difference. At the condensing unit pressures and charge were good. Electrical components were good. Coil is rinsed clean. For the upstairs system static is failing running at twice the max. Blower wheel is dirty. Motor amps were good. There is a 14 degree temperature difference. At the condensing unit pressures and charge look good. The capacitor has failed. Unit is rinsed. Declined to replace capacitor today. Systems are running upon departure. Thanks for choosing LBA.
Arrived to remedy a system that is not cooling. Upon inspection of the system found everything operating the way that it should. Connected refrigerant gauges to the system and found that it is low on refrigerant. System could be leaking but homeowner says it has not cool the house since it was installed. System is in need of refrigerant and a leak search.
Went for a service call today. There was no oil leaks on system, just moss growth around the system. Will recommend to get power washed to have removed. No leaks on system and all working well. Thank you for choosing LBA services-Johann
Arrived for dampers not working. Found that the transformer failed. Piggybacked voltage and all dampers are working correct. System is running upon departure. Thanks for choosing LBA.
Upon arrival I spoke with Mitch and John. They relayed to me that the condenser’s fan motor is running however the compressor may not be running. What I discovered is that the wire from the common terminal on the capacitor to the contactor was not in position on the contactor and had fallen off. I checked the capacitor then reattached the wire. The condenser returned to normal function. The temp differential was at 16degf with a high humidity load. They had just recently had some mulch laid in around the unit and the thermostat wire inside the unit is wire tied from the factory to the wire that became unattatched. Thank you, Jon
Replacing furnace with properly size furnace we did not install properly last time well I
Arrived for ac check. Upon passing inspection I found that we had installed the wrong size furnace last January. I talked with my manager and she sent Lane out to get you taken care of. Thanks for choosing LBA.
-Cut cast iron coming from bathroom group under slab part of home -Remove all leftover horizontal cast iron on main sewer line -Replace main sewer line drain and fittings with newer pvc Check operation
Arrived for ac check today. Started at furnace and checked static pressure, it is failing. I changed furnace filter. Motor amps are good. There is an 18 degree temp split. At the condensing unit all pressures and charge look good. All electrical components are running within manufacturing specs. The contactor is starting to pit. I rinsed coil clean. System is running upon departure. Thanks for choosing LBA.