6850 West 47th Tr
Mission, KS 66203
(913) 268-6822

Local Reviews
for bucyrus, ks

Rated 5.0 out of 5 stars based on 5 customer reviews

Awesome service, Good price

The technicians were very professional and did a wonderful job installing our new system. They arrived promptly and did great work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

this man was Professional,

Kevin helped me understand my Heating and air. Kevin is the only guy I want at my House. kim and Bill Hickey

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for bucyrus, ks

daniel.aguilar@lbaservices.com

daniel.aguilar@lbaservices.com Job Checkin

Performed blower Clean as well as replaced UV light bulb and humidifier canister. Make sure all three systems ran properly before leaving.


daniel.aguilar@lbaservices.com

daniel.aguilar@lbaservices.com Job Checkin

Heating maintenance X3. Checked all task. Checked heat strips. Checked blower motors and wheel upstairs system had biological growth growing on the wheel. Checked humidifiers. Checked outdoor systems. Checked capacitors. Checked refrigerant levels. Checked coils and clean. Recommended replacement of contactor air filter UV light canister to humidifier and blower wheel customer approved. Make sure system room before leaving View visual findings from this job here - https://visionshare.xoi.io/?id=XA-3881-D911A96214BC4F29988D817F1205FB9C


Kaden T.

Kaden T. Job Checkin

Company arrived Thursday, September 1, 2022. The customer was having issues with their floor drain next to their water heater draining slowly and was interested in replacing the expansion tank to the water heater. Company opened the slow draining floor drain via toilet auger allowing for proper flow. Company gave estimate for the expansion tank replacement and the customer chose to have the work preformed today. Company removed the failed expansion tank and replaced it with new. This will come with a 2 year warranty on parts and labor. Thank you for choosing LBA and have a great day.


Jackson C.

Jackson C. Job Checkin

Client called because AC wasn't cooling. Ran a diagnostic and found the thermostat was faulty. Replaced the old digital thermostat with a new programmable thermostat. Tested the replacement thermostat and AC began cooling right away.


Andrew P.

Andrew P. Job Checkin

Return to perform warranty work. System is working as designed at this time.


Andrew P.

Andrew P. Job Checkin

Warranty Found system not turning off when auxiliary heat come on when thermostat is satisfied with in the heating cycle. Turned thermostat to heat pump only mode system would cycle properly and auxiliary heat will not turn on currently. We will return when Bosch technical support responds with a solution. System was cycling properly in heat pump only mode. We will return when we have a permanent solution. Thank you


Nick L.

Nick L. Job Checkin

Warranty check up Systems auxiliary heat was turning on almost immediately as system turned on. Checked Temperature splits of heat pump was 22⁰ and with auxiliary was 36⁰. Changed setting on thermostat to not turn on auxiliary Heat on design till the Temperature is 10⁰ (origially 3⁰ manufacturers specifications) colder than the requested temperature or until the heat pump is running constantly for 15 minutes (originally 10 minutes manufacturers specifications) unless a call for defrost on heat pump is needed. System was not immediately turning on auxiliary heat when call for heat was requested from the thermostat. System operating when technicians left.


Patrick  K.

Patrick K. Job Checkin

Arrived to troubleshoot a noise coming from the air conditioning system. Began investigation at the furnace. Ran air conditioning diagnostic. Found that the blower motor was making excessive noise when the thermostat would satisfy. Verified that the noise was just the blower motor. Ordered the parts and installed a whole new blower assembly. Verified that the system is operational and no longer making excessive noise. Air conditioning system is functioning properly at this time.


Walter I.

Walter I. Job Checkin

08/05/2021 11:35:01 AM - Option 1 <a clicktracking="off" href="https://partsgatorstorage.blob.core.windows.net/proposals/852021 45943 PM - 1 - 13-080521113501-Dave Harkleroad-Proposal-Copy.pdf?sv=2014-02-14&sr=b&sig=PeNIppTowE0G6HLQZ1cGK1FbeTIUGh%2FCDnL8kLkzKzo%3D&st=2021-08-05T18%3A15%3A09Z&se=2521-08-05T18%3A20%3A09Z&sp=rw" target="_blank">View PDF</a>


Nick L.

Nick L. Job Checkin

System has a major refrigerant leak in the a coil and the customer wanted to look into replacement of the heat pump.


Patrick  K.

Patrick K. Job Checkin

Arrived to do performance maintenance. Inspected the air conditioning system to verify operation of all mechanical and electronic components. Verified system charge and temperature split. Changed filter with homeowner supplied filter and cleared condensate line. Air conditioning system is functioning properly at this time.


Jeremy A.

Jeremy A. Job Checkin

Customer is applying for financing.


Jeremy R.

Jeremy R. Job Checkin

Found floor drain in mechanical room not draining. Turned off water to humidifier. I am going to have a plumber come out in the morning 23 Jan 21.


Austin J.

Austin J. Job Checkin

Warranty call company installed electric Rudd water heater for warranty and customer called back in saying that water was still not hot. Upon arrival noticed tankless system feeding hot water tank temperature was set at 135 and heating elements in Rudd tank were factory set at 115 Causing elements to trip on relay system. Went ahead and pushed reset button On heater and elements started firing then adjusted temperature to 125 on both elements and turn the temperature down on tankless system going into tank itself to prevent water heater from overheating. After turning heater back on water started to heat back up use temperature gauge to test water after waiting 10 to 15 minutes and water temperature was up to 120 and still climbing checked voltage on both elements in both elements are firing properly everything is testing OK at this time.


Austin J.

Austin J. Job Checkin

Customers two year old Ruud 50 gallon electric water heater is leaking from base. Went Ahead and checked pressure on household itself, pressure regulating valve and thermal expansion tank or operational customers incoming pressure is at 65 psi so company can honor manufacture warranty on replacement of tank itself. Company will also replace 4.5 gallon expansion tank and Company Will honor 30 day installation warranty on new heater expansion tank. Company returned following day on August 6, 2020 to conducted warranty swap out of 50 gallon electric ruud water heater. Company Also installed two new ball shut off’s for hot and cold side, New 4 gallon expansion tank with pressure set at 68 psi. After installation was complete turned water on to test all fittings and fill tank itself after tank was full turned on electric elements to start heating tank itself, Can conclude that installation is testing OK at this time and customer will have 30 day warranty on installation itself. Thank yo