6850 West 47th Tr
Mission, KS 66203
(913) 268-6822

Local Reviews
for bucyrus, ks

Rated 5.0 out of 5 stars based on 6 customer reviews

Very helpful

Very intelligent and well spoken and patient.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service, Good price

The technicians were very professional and did a wonderful job installing our new system. They arrived promptly and did great work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service


Response from LBA Air Conditioning, Heating & Plumbing:

Many thanks for taking the time to share your feedback with us. We’re very happy to hear that we met your expectations

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

this man was Professional,

Kevin helped me understand my Heating and air. Kevin is the only guy I want at my House. kim and Bill Hickey

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for bucyrus, ks

Charles G.

Charles G. Job Checkin

Water Softener Installation: Installed a compact and efficient water softener system to address hard water complaints. The solution eliminated issues like soap scum, dry skin, and clogged fixtures, providing the client with noticeably improved water quality.


Josiah W.

Josiah W. Job Checkin

Left voicemail


Josiah W.

Josiah W. Job Checkin

Arrived at home and spoke with Brad about reason I was called today, which was to do an inspection of homes fridge water. He’s been having a weird metallic taste. Come out of the fridge for the last month and want to know why it was, after running test, and taking a look at the rate piping was ran. I’ve determined that the issue with the taste is probably due to the filter, being old and the amount of chlorine and pH in the water. He let me know that he wanted a quote for a water softener infiltration to eliminate the bad water from the home that way it’s better for their skin, health and homes piping. Collected signatures and headed out.


Patrick  K.

Patrick K. Job Checkin

Arrived to do a performance maintenance on an airhandler and a minisplit system. Checked operation of the airhandler. Made sure the thermostat will handle the changeover between the heat pump and the electric heat strips. Checked heat strips for function. Checked over system for cleanliness. Replaced furnace filter. Switched over to the minisplit system and verified the temperature split. Cleaned minisplit filters. All systems are operating properly at this time.


Addison L.

Addison L. Job Checkin

8/15/2024 Upon arrival, customer stated tub is splashing out of the tub and water pressure is low turn the water pressure up to 80 and looked into the tub and got tit to splash less Vitals: -Water Pressure Static: 80 -Water Pressure Faucet Open: 75 After reviewing the entire house I went over everything with mrs.kulp to ensure they understood everything going on in the house and what could be done to address it. (Getting supervisor out?) Thank you for choosing LBA Services Your technician, Addison


Lee M.

Lee M. Job Checkin

Assist Addison and Chris on customer service


byron.dorris@lbaservices.com

byron.dorris@lbaservices.com Job Checkin

A home's sewer line was experiencing frequent backups due to tree roots infiltrating the pipes. Once we found the problem. we used advanced equipment to remove the roots and repair the damaged section.


David W.

David W. Job Checkin

Upon arrival main water was shut off to water heaters, drained out and disconnected 2 old 50 Gal State Water Heaters and installed 2 new Rheem Performance Power Vent water heater install new ball valves and re-circ pump. Tested for leaks by filling both water heaters and airing out all lines through all fixtures in home. All good no leaks present and all fixtures are working properly.


byron.dorris@lbaservices.com

byron.dorris@lbaservices.com Job Checkin

DATE - 7, august 2024 Performed full home inspection Vitals: -Total Dissolved Solids: -Water Pressure Static: couldn’t test, water turned off -Water Pressure Faucet Open: -Water Temp Setting: 125 -Water Temp Output: -Water Hardness: 0 -Water Quality: 0 chlorine, 7.5 ph -Water Heater: failed, dual 50 gallon gas power vent with recirculating pump -Water Lines: pex -Drain Lines: pvc Wear and Tear: water heaters failed After reviewing the entire house I went over everything with homeowner to ensure they understood everything going on in the house and what could be done to address it. Solutions: replace both water heaters and recirc pump Services done today: performed whole home inspection, gave quotes for dual water heater replacement Thank you for choosing LBA Services Your technician, mick ____


Lee M.

Lee M. Job Checkin

Water heaters


Robby M.

Robby M. Job Checkin

Unable to access


Tyler R.

Tyler R. Job Checkin

Upon arrival I began the AC tune up. First, I did a static pressure test on the system. The manufacturer has it rated for a maximum of .5 and your system is testing below that at .2 which passes the static pressure test. I then noticed the drain from the evaporator coil inside was backed up with some debris. I cleared the drain and it’s clearing properly now. I checked the running amps on all the motors and they were within specifications. The refrigerant levels were not making any sense. The numbers were jumping up and down. I believe the TXV, which is the refrigerant metering device, is not working correctly by allowing the correct amount of refrigerant into the evaporator coil. I have spoken with my manager and we want to have another senior technician and a field supervisor to come take a look and figure out what exactly is causing this. The air is cooling the home well in the meantime. I will lock in a good time for Eric, the tenant, to come back over tomorrow if he’s available. I


Johann A.

Johann A. Job Checkin

Went for a maintenance call today upon arrival. Customer stated house is cooling properly. When checking air handler, static pressure was passing capacitor and blower wheel. Amps were good as well as blower wheel was clean. Temp split was good as well. When checking the outdoor unit did clean it out. Capacitor was good as well. Refrigerant levels were good. Due to temp split. Fan amperage were good as well. System is up and running. Thank you for choosing LBA services.


Jesse R.

Jesse R. Job Checkin

Dc


Graham W.

Graham W. Job Checkin

For this job, I was repairing a steam humidifier. Upon checking it was clear that there was a gasket valve loose and it was leaking from the bottom of the canister. Replace the gasket valve and sealed it off with pipe sealant. Turned it on and let it run for a while to ensure that they were no leaks and it was operating properly. Everything is working as it should at this time. Estimate