Patrick was able to find out the issue and why my new furnace was not heating. They did it quickly and efficiently as always.
Installed a new HVAC system and explained everything when it was done. Went over the new thermostat they installed. Ask if I had any questions about the new system. I just wanted to make sure I was comfortable with it all.
Scott came out, reviewed my options on my furnace with the service tech. Once this was done came up and gave me my options and explained the difference in the options.
Patrick is always very professional. Explains things in terminologies that you can understand. Patrick will answer as many questions as you have, even if you’ve already ask him before.
Patrick came to to help us out with our AC and diagnosed the issue. Very friendly and honest. Glad he said as there.
I have been in business for over 45 years & seldom see service techs that are on time, professional, polite & of course knowledgeable, I only recommend LBA & myself a satisfied customer!
Explained everything they were doing during AC tune up, including showing me the readings on the cap on the AC unit and provided an estimate to replace. Talked about new member savings program.
Jeremy explained what they were going to do with my duct work. Cleaned all of my ducts. Explained everything and showed me all the work they did once it was completed.
Patrick came out, diagnose the issue with my furnace, not working properly and fixed it. Professional as always, and answered all my questions.
Quoted customer for new water cylinder on Humidifier. Looked at unit heater and found fan motor locked up. Called carrier and part is no lo ger available due to age. Will send quote for new system.
Completed furnace inspection for customer. Components tested within manufacturer specification. Static pressure was failing running at almost double the value allotted. 2ppm of Carbon monoxide detected, inspected heat exchanger and it visually appears to be in good condition.
Customer called stating system wasn’t operating properly. Found that the signal was breaking at the thermostat. Once corrected furnace ran for about 5 minutes and then flames continued dropping out and relighting, found that gas valve relay is faulty. Blower motor was leaking oil. Customer is opting to replace furnace. Turned over to field supervisor for further advisement.
Arrived to do a performance maintenance. Set up for combustion analysis temperature split and static pressure tests. Found that the system operating with failing static pressure. Tried to relive enough static pressure to bring the system within manufacturers specifications, but was unable. Set up for a field supervisor to finish the diagnosis on Thursday at 2pm. Verified operation of all mechanical and electronic components of the furnace. Cleaned the flame sensor and retested its performance. Checked blower for cleanliness and to see if there is any play in the bearings. Checked systems heat exchanger to ensure proper venting of flue gas. Found rust present where the heat exchanger is prone to failure. Found lots of debris filling the cracks in the ductwork. Used the inspection camera to look inside the ductwork. Found excessive debris built up inside the ductwork. Furnace is operational at this time.
Went for a maintenance call today. Tested for static pressure. System is passing for static. Did a cfm count is short on supply. Based off going on national duct sizing. Did a co test, no co was detected when testing. Inspected heat exchanger no wear and tear. All electrical components are passing for system. Temp split passes for system. Drain line, pressure switch hose and flame sensor are clean. As well as blower wheel. No further wear and tear on system. Thank you for choosing LBA services-Johann.
Arrived for furnace maintenance today. Checked static pressure and found it is failing. A field supervisor is out to look further into that. Carbon monoxide test was 0 ppm. Heat exchanger has some rust forming. Blower wheel needs to be cleaned. All electrical components are running properly at this time. System is running upon departure. Thanks for choosing LBA.
12/4/24 - Completed a full heating maintenance on all equipment. All filters were changed, belts were checked, heat exchangers were checked, and proper operation was tested. Overall, all equipment was in good condition, it was running well, and there were no issues found at this time.
Installed an 80% furnace, communicating with furnace box and T-Stat
This system was installed correct for the condensation to drain proper. Old line was clogged that we were using. I reinstalled old condensation pump back into the new unit and ran lines to it. Ran system threw all functions and there is no leak anymore.