1. Install dual function breaker Homline 2. Install tandem breaker Homline 3. Replace 3 outlets in kitchen 4. Troubleshoot plugs in kitchen and pigtail 5. Feed wire from main panel to sub Customer was having issue with three kitchen plugs, not working properly and one of them were controlling the fridge. I had to relocate the wire from main panel to subpanel and install dual function breaker. Had to install tandem breaker to make room and panel. Replaced all three plugs and the third plug control in the fridge Was completely burnt and melted and shorting out on the metal box. Explain to customer it is a hazard, especially with aluminum wiring and that the panel is very outdated. Everything is working at this time and will only warranty circuit if he doesn’t use toaster oven or anything major that heats up on that same circuit with the fridge. As long as he doesn’t use anything else, we will warranty the circuit until he gets a dedicated circuit for fridge. We are returning with Ma