Arrived on-site to complete a whole-home safety inspection. Inspected all areas throughout the house and identified several code violations and concerns that need to be repaired. One issue is double-lugged neutrals and grounds inside the panel, which need to be separated into their own individual lugs. This can cause connection issues and result in improper power distribution due to loose or incorrect wiring. Additionally, there is a single-pole breaker installed that is not UL-listed for a Square D Homeline panel, which will need to be replaced with a proper listed breaker. I also found an exposed large Romex cable running from the conduit to the ground outside. It appears to go under the patio set, but it’s unclear what it controls. This cable needs to be capped off or properly terminated in a weatherproof box. Noticed as well that the four hardwired smoke detectors in the bedrooms are not connected to their harnesses. They are not battery-operated units, so they will need to eithe