Completed (2)plan AC tune ups First Floor system 5 Tons Second floor 2.5 Tons Replaced 20x20x1 filter for attic syste (ceiling return grill) Basement washable filter ok For BOTH Systems: Inspected wiring, controls, electric motors and components: Homeowner asked that I install an Ecobee Pro for the first floor system. Completed work today including connecting thermostat to Wifi and registering thermostat. Thermostat and room sensor are connected to app. Set electric heat lockout to 38°F Inspected drains Measured temperature split and static pressure Inspected condition of both the indoor and the outdoor coil. Monitored R410A refrigerant pressures and diagnostics for both systems: Good Both systems operating well at the time of tune up. Homeowner paid for Ecobee Pro thermostat install today.