Joseph D.

Joseph D.


Job Checkin

Reviewed job with customer. Checked over all wiring and accessories to ensure everything was wired correctly. Found spade connector bare at outdoor unit connected to high pressure switch, taped connection. Taped around connections to added high pressure switch. Removed and replaced 40/5 capacitor and installed SPP6 start kit on unit. Tested operation of heat pump and measured refrigerant charge and compared with chart. Unit was running to specifications. It started raining so I needed to button up outdoor unit before I could test defrost cycle. If problem persists, recommend testing defrost operation and installing manual reset high pressure switch to determine if unit is going off on high pressure.