Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
Completed tune up for BOSCh Inverter 5 To 20SEER: Homeowner replaces 20x25x5 filter annually. I recommend replacing every 6 months. He uses MERV 16 filters for allergen control. He said he will replace more often now, Measured temperature split and static pressure. Inspected condition of indoor and outdoor coil Checked ez trap, drain and components Inspected wiring, controls, electric motors and components. Left estimates for surge protection for indoor blower motor. Also left estimate for APCOX whole home air purification system. Monitored R410A refrigerant pressures and diagnostics. 117/232; Subcooling 8° System is operating well at this time.