Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
Performed heating maintenance, checked air filters ok. Serviced gas furnace, cleaned burners and flame sensor, inspected heat exchanger. Checked voltage, amperage and electrical connections. Blew out condensate trap and drains. Started gas furnace, tested limit and safety switches, measured fuel pressures. Performed combustion test. Checked operation and temperature rise. Second heat pump, checked voltage, amperage and electrical connections, measured capacitor values. Started heat pump, tested defrost cycle. Checked refrigerant charge and temperature drop across coil.