Completed plan member heat tune up for 80,000 BTU natural gas furnace Replaced 16x25x1 filter Inspected burners, heat exchanger, ignitor, inducer assembly, pressure switches and components Cleaned flame sensor with and verified flame rectification circuit Inspected wiring, controls, electric motors and components; there is no 120V switch at furnace. left email estimates for surge protection devices. Switch must be installed to be able to install surge protector. Confirmed proper manifold gas pressures Confirmed inducer vacuum in low and high fire operation Measured temperature rise and static pressure Inspected all components of drain Combustion, smoke and draft tests: Pass Indoor AC coil very rusted. Discussed and left estimate for AC+Gas Heat plan Membership. Furnace is operating well at the time of this tune up.