2 Ton Mini split System with 1 indoor head in living room area. Found washable filters very dirty. And consequently low blower speed an poor performance. After cleaning washable filter, tested operations. Temperature rise (71-98= 27⁰) Good. Outdoor ambient temperature 48⁰F. Checked refrigerant pressures and diagnostics. 322 psi Good During run time approx 45 minutes. Primary thermostat temperature which is located in sane rose 4⁰ from 72⁰ to 76⁰ Checked for any obvious refrigerant leaks. Left estimate for plan memberships one for Mini split System. 1 for Oil furnace. Also discussed and left estimate for surge protector. Mini split System is operating well at this time. Collected diagnostic fee today.