Nathen is a good Technician and takes pride in his work. He is very courteous to the customer if you have a question he will answer it with no problem. I would recommend him to family and friends to take care of there plumbing needs.
The technician was on time, he explained what he would do, the terms of the work, how long it would take him. He was polite, and put on the shoe protectors when he entered the house. He did his work in the time that he said he would. When he finished he wiped up under the sink and turned it on and I could hear the water going swiftly out the drain. I was very pleased with his work and his manner.
Christian was incredibly knowledgeable and was able to fix our water issues same day!... Would recommend him and Vern Plumbing!
I have worked with 3 companies over the years. Vern’s is by far the best I have worked with. Scheduling is easy and the are always on time. Beyond that they deliver quality work. I am always impressed by their professionalism, attention to detail, and their desire to make sure the customer needs are met to our satisfaction. I’ll be staying with them for years to come.
Carlos was prompt and courteous. He replaced my outside faucet and sealed up the area around the faucet enough so rain wouldn’t get in again which is what likely caused the pipe to freeze and weaken. He was able to remove the stuck hose from the faucet. I’m very pleased.
Install new 50 gallon electric water heater
Found heater was leaking internally towards the upper element This will require the heater to be replaced, left Larry with estimate to replace with a new 50 gallon electric Retuning tomorrow to install between 10-12
Looked at roughly 5 year old pump Pump was still cycling fine and did not make any rough or loud sounds during cycle Customer was customer about life spans of sump pumps, mentioned the life span can vary, but it’s pretty typical these zohler sumps last 10 years or so Emailed estaimte for the replacement of a sump pump and battery backup
Emailed carol estimates for new pressure assisted toilet as well as a standard flush toilet
Snaked toilet with closet auger and adjusted chain height to allow for a more powerful flush from the toilet An incomplete flush was the cause of the blockage in the toilet, mentioned to customer allowing more water per flush will help correct issues with the toilet backing up, They had questions about having the flooring replaced, asked if the toilet should wait until then to be installed Yes. It’s easier to rework a flange to the new floor height than it will be to work the floor around the new flange Waiting until flooring is replaced is the best option for the new toilet Resent existing quote for toilet
Cleared kitchen sink blockage with k50 sewer machine, sink is now draining as it should with no issues. Retrieved tons on grease on my cables once I pulled them back. If this issue keeps occurring in the future we need to return to clear the line out with the box jetting machine. Applied 10% senior citizens discount to today’s invoice. Emailed copy of invoice and estimates to homeowners email.
Wrote estimate to install 1054 IMP water right water softener and ultra violet light. Don’t know if the ultra violet is 100% needed for this system. Sent a water sample off to Joyner laboratory today, we should have the test results back by tomorrow afternoon. Please contact the homeowner once the results have been received. Emailed copy of invoice and estimates to homeowners email. Water test results Hardness- 6 Iron- 0.2 PH- 8.0 TDS- 8.0
Put the p trap in the double sink in the master bedroom run water to see any leak and no leaks found also show to the owner job is is complete
Customer was having pressure issues with the well pump not giving enough pressure. Pulled the pump and found that the pump was cracked and was why it wasn't able to hold pressure and was constantly running. The pump by the time we arrived was only holding 30 psi. Replaced the pump the wire and the water line leading down the well. Also replaced the pressure tank and added a brass ball valve at the other side of the tank and removed the old dead head valve before the tank. Took apart filter and retighted the filter
Gave customer estaimte on the installation of a new shower valve in the hall bathroom, this is a customer supplied Allen and Roth shower valve, due to the limited space within the wall/closet area there is a possibility the shower valve will not fit properly within the wall Mentioned to customer alteration to the wall inside of the closet could be made to make this fit should it be necessary However at the time with the closet being full the technician cannot access the panels Emailed estimate and talked over quote with the homeowner
Customers toilet was clogged again. I ran an auger through it. Flushed toilet multiple times after to test.